The Munot becomes smart
- Country CH, Schaffhausen
- Build year 16. Jahrhundert
- LOXONE partner Elektro Meister AG

Challenge
- Installation in accordance with historic preservation regulations: Close coordination with the preservation authorities to minimize interference with the historic structure.
- Technical integration: Precise interplay of DALI, DMX, and sensors in a single system.
- Operational reliability: Reliable operation for everyday use and events.
- Technical integration: Precise interplay of DALI, DMX, and sensors in a single system.
- Operational reliability: Reliable operation for everyday use and events.
Solution
- Automated DALI lighting with approximately 130 luminaires on the battlement
- Two control levels for maximum user-friendliness:
+ Everyday scenes: predefined lighting moods
+ Event mode: for events, resets automatically
- Sensor-based control for energy-efficient use of the restroom facilities
- Load management in the Munot guard's apartment
- Integration of DMX wallwashers for targeted lighting accents
- Variable fading times according to lighting design specifications
- Two control levels for maximum user-friendliness:
+ Everyday scenes: predefined lighting moods
+ Event mode: for events, resets automatically
- Sensor-based control for energy-efficient use of the restroom facilities
- Load management in the Munot guard's apartment
- Integration of DMX wallwashers for targeted lighting accents
- Variable fading times according to lighting design specifications
Loxone offers us the flexibility and reliability we need for such a sensitive and demanding project as the Munot.
Lukas Meister, Owner of Elektro Meister AG
Products
- Miniserver Compact · 100512
- Dimmer Extension · 100029
- DI Extension · 100283
- DALI Extension for 64 Devices · 100200
- DMX Extension · 100012
- Relay Extension · 100038