The Shade Control Air brings Silent Gliss 50 Series tubular motors into LOXONE Automatic Shading: glare-free daylight, no overheating, privacy in the evening. The Air interface connects the motor to the Miniserver wirelessly - no gateway, no data cabling.

Datasheet Shade Control Air for Silent Gliss 50 Series

Table of Contents


Mounting↑

Install the Silent Gliss 50 Series motor according to the manufacturer's instructions.

Then attach the +24 V and GND wires of the plug connector to the 24 V motor power supply and plug the Shade Control into the Silent Gliss 50 Series motor as shown in the wiring diagram below.


Commissioning↑

In delivery state, pairing mode will be active after the power supply has been established. This is indicated by the status LED flashing red/green/orange.

Then follow the pairing procedure on the Air Interface.

To activate the pairing mode manually, switch off the power for 10 seconds, then switch it back on. If no connection to a Miniserver can be established for two minutes, then pairing mode is activated for 5 minutes.


Programming↑

The LOXONE Shade Control is programmed and set up using the Automatic Shading integrated function block in LOXONE Config:

In the device properties, the duration of a complete movement can be configured. The device reports the actual travel range of the motor, allowing shades of different lengths to reach their end positions simultaneously.

The movement direction can also be inverted depending on the installation, ensuring that the up and down commands in the LOXONE App correspond to the actual movement.

The end limits can be set or adjusted directly in the LOXONE App under "Service Mode". The movement direction can also be changed here.


Actuators↑

SummaryUnit
API ConnectorText




Diagnostic Inputs↑

SummaryDescriptionUnitValue Range
Online Status Shade Control Air for Silent Gliss 50 SeriesIndicates whether the device can be reached by the Miniserver.
Diagnostics for Air devices
Diagnostics for Tree devices
Diagnostics for Extensions
Digital0/1
System temperatureProvides the internal device temperature.
This is often the temperature of the CPU or another location in the device.
°∞
Temperature ShutdownInput is active, when the outputs of the device have been switched off due to high device temperature. Possible reasons: Ambient temperature too high, outputs overloaded.Digital0/1
Motor in motionDigital0/1
Motor blockedDigital0/1
Obstruction detectedDigital0/1
Learn Mode-∞




Properties↑

SummaryDescriptionValue RangeDefault Value
Monitor online statusIf checked, you will be notified via System Status or the Mailer if the device is no longer available or goes offline.--
Disable Repeater functionalityDisable repeater functionality of this Air device.

LOXONE Air is based on mesh technology. Any air device connected to the power supply can repeat packets from other Air devices, thus extending the range and stability of the overall system.
In large systems with a large number of air devices in a confined space, the communication between the air devices can lead to a very high radio channel utilization. A reliable accessibility of the air devices can not be guaranteed. Disabling repeater functionality on individual Air devices can help.

Do not disable this function recklessly as this may affect the range and stability of the system.
--
Serial numberSerial number of Air device.
Automatic pairing can be enabled on the Air Base.

Automatic pairing can be enabled on the Airbase for a set time.
--
Duration of complete movement [s]Duration of complete movement in seconds1...60030
Inverted DirectionInvert direction. Required when Up/Down connection is made the wrong way round.--



Safety Instructions↑

Installation must be carried out by a qualified electrician in accordance with the applicable regulations.


Documents↑

Datasheet Shade Control Air for Silent Gliss 50 Series