The LOXONE Ceiling Light Pure RGBW Air is a downlight with an integrated presence detector and brightness sensor that combines high-quality white light from 2 200 K to 6 500 K with vibrant colored light. Control and dimming are handled directly via the integrated Air interface.
Datasheet Ceiling Light Pure 12 RGBW Air
Datasheet Ceiling Light Pure 17 RGBW Air
Table of Contents
Mounting↑

Mount the ceiling mounting base and connect the power supply (orange/orange-white terminal).
Hang the light fixture from the ceiling mounting base using the steel cable.
![]() | The steel cable serves as a safety cable and must not be removed! |
Then plug in the connector between the luminaire and the ceiling mounting base.
Align the three magnets with the flat areas of the ceiling plate. Push the luminaire upwards and turn it until it locks into place. Make sure the markings are aligned and no wires are pinched between the magnets.

Commissioning↑
For commissioning, the device must be supplied with power and a connection to the Miniserver must be possible via the Air Interface.
Then follow the pairing procedure on the Air Interface.
To manually activate pairing mode, disconnect the device from the power supply for 10 seconds and then power it on again. If no connection to the Miniserver can be established within two minutes, pairing mode is activated for 30 minutes.
Sensors↑
| Summary | Description | Unit | Value Range |
|---|---|---|---|
| Volume Minimum | Provides the minimum volume periodically based on the value set in "Volume Transmission Cycle". | - | 20...2000 |
| Volume Maximum | Provides the maximum volume periodically based on the value set in "Volume Transmission Cycle". | - | 20...2000 |
| Brightness | Provides the measured value of the current brightness. Value is not updated when the light is on | Lx | ∞ |
| Motion | Input is active when motion is detected | - | 0/1 |
| Presence | Input is active as long as presence is detected. Motion activates the input, volume and motion keep it active. | - | 0/1 |
| Sound level alarm | Input provides a pulse when the volume exceeds the threshold for the sound level alarm. 1 pulse per 10s. | - | 0/1 |
Actuators↑
| Summary | Description | Value Range |
|---|---|---|
| Smart Actuator | The minimum fading time is 1s. | ∞ |
Diagnostic Inputs↑
| Summary | Description | Unit | Value Range |
|---|---|---|---|
| Online Status Ceiling Light Pure RGBW Air | Indicates whether the device can be reached by the Miniserver. Diagnostics for Air devices Diagnostics for Tree devices Diagnostics for Extensions | Digital | 0/1 |
| System temperature | Provides the internal device temperature. This is often the temperature of the CPU or another location in the device. | ° | ∞ |
| Temperature Shutdown | Input is active, when the outputs of the device have been switched off due to high device temperature. Possible reasons: Ambient temperature too high, outputs overloaded. | Digital | 0/1 |
Properties↑
| Summary | Description | Unit | Value Range | Default Value |
|---|---|---|---|---|
| Monitor online status | If checked, you will be notified via System Status or the Mailer if the device is no longer available or goes offline. | - | - | - |
| Disable Repeater functionality | Disable repeater functionality of this Air device. LOXONE Air is based on mesh technology. Any air device connected to the power supply can repeat packets from other Air devices, thus extending the range and stability of the overall system. In large systems with a large number of air devices in a confined space, the communication between the air devices can lead to a very high radio channel utilization. A reliable accessibility of the air devices can not be guaranteed. Disabling repeater functionality on individual Air devices can help. Do not disable this function recklessly as this may affect the range and stability of the system. | - | - | - |
| Serial number | Serial number of Air device. Automatic pairing can be enabled on the Air Base. Automatic pairing can be enabled on the Airbase for a set time. | - | - | - |
| Lighting Group | Assigned Lighting Group. To create a new group simply start typing a name. | - | - | - |
| Volume threshold presence | Minimum sound level to detect presence | - | 20...2000 | 250 |
| Volume threshold sound level alarm | Minimum volume to trigger sound level alarm | - | 20...2000 | 1000 |
| Volume thresholds | Configure the volume thresholds using a graph of the current volume | - | - | - |
| Overrun time presence | Overrun time for presence input. | s | 2...60000 | 300 |
| Overrun time motion | The 'Motion (Mo)' input remains active following the last detected motion for the set time. A higher value means less packets have to be sent via Tree and Link. If the motion detector is used for the alarm system, the time is automatically set to 3 seconds when the alarm system is armed. | s | 2...900 | 60 |
| Volume transmission cycle | Transmission cycle for minimum and maximum volume (1-3600 sec, 0=off) | s | 0...3600 | 300 |
| Brightness transmission cycle | The brightness is transmitted periodically at the set transmission cycle (0=OFF). In addition, the brightness is transmitted when presence is detected or when there is a change of at least 30%. If the brightness is used by a Constant Brightness Controller, it is transmitted at a change of 5%. | s | 0...7200 | 900 |
| Presence duration without motion | Presence ends when no motion has been detected for this duration. This prevents constant ambient noise from keeping presence active. Before using this function, check if the volume threshold for presence is set accordingly. 0 = Disables this function. | s | 0...60000 | 1800 |
| Sensitivity | Effects the sensitivity and thus also the distance over which motion can be sensed | - | - | - |
Safety Instructions↑
Installation must be carried out by a qualified electrician in accordance with the applicable regulations.
Documents↑
Datasheet Ceiling Light Pure 12 RGBW Air
Datasheet Ceiling Light Pure 17 RGBW Air