If an error occurs, the corresponding error code is sent from the Wallbox to the Miniserver and displayed in the LOXONE System Status.
| Code | Title | Description |
|---|---|---|
| 101 | Fault Current | A fault current was detected during operation. |
| 102 | RCD Init Timeout | The internal RCD did not complete initialization within the expected time. |
| 103 | RCD Test Timeout | The internal RCD did not respond during the self-test. |
| 104 | RCD Test Failed | The internal RCD self-test failed. |
| 105 | RCD Supply Fault | The power supply of the internal RCD dropped or is unstable. |
| 201 | Unexpected State | The EV entered an undefined or unsupported state during charging. |
| 202 | RCD Not Ready | The internal RCD is not ready for operation. |
| 203 | No Pilot Diode | The pilot diode was not detected in the vehicle. |
| 204 | Digital Communication | An unsupported digital communication standard was detected. |
| 205 | Ventilation Required | The EV requests external ventilation before charging can continue. |
| 206 | Phase Switching Timeout | After a phase switching event, the EV does not resume charging within the expected time. The charging process remains in a non-ready state. |
| 300 | Voltage Dip | A voltage dip in the power supply was detected. |