The Door Lock Air is a wireless door lock based on LOXONE Air technology. It provides remote control and status feedback of doors via the LOXONE system, suitable for new builds and retrofit projects.
Inductive variants (Full Leaf / Tube Frame): Inductively powered, maintenance-free, no battery replacement required.
Battery variants (Full Leaf / Tube Frame / Glass Doors): Battery powered, ideal for retrofitting without additional wiring.
Datasheet Door Lock Air Inductive
Datasheet Door Lock Air Battery
Datasheet Door Lock Air Battery for Glass Doors
Table of Contents
- Mounting Door Lock Air Inductive
- Mounting Door Lock Air Battery
- Mounting Door Lock Air Battery for Glass Doors
- Commissioning
- Inputs, Outputs, Properties
- Safety Instructions
- Documents
Mounting Door Lock Air Inductive↑
Insert the Door Lock Air into the door leaf:
![]() | The auxiliary latch must not engage with the strike plate. |

The markings on both the transmitter and receiver units must be aligned, and the gap between the two components must be 2–3 mm to ensure optimal inductive power transfer:

Adjusting the inductive power transmitter
The transmitter module can be slightly adjusted in both height and depth to ensure precise alignment with the receiver unit.
| A) Adjust height | B) Adjust depth (gap) |
|---|---|
| 1. Loosen the screws. 2. Slide the module to the desired height. 3. Tighten the screws. | 1. Remove the screws. 2. Add or remove spacers until the correct gap is reached. - Recommended gap: 2–3 mm (max. 5 mm) 3. Tighten the screws. |

Mounting Door Lock Air Battery↑
Insert the Door Lock Air into the door leaf:
![]() | The auxiliary latch must not engage with the strike plate. |


Insert the supplied batteries into the device:
![]() | The DIN standard Door Lock Air requires 2 x AAA batteries. The Ö-Norm and tube frame Door Lock Air requires 1 x 1/2 AA (LS 14250) battery. |

![]() | We recommend using lithium based batteries. |
![]() | CAUTION: There is a risk of explosion if the battery is replaced improperly. The replacement must only be with the same or specified type. Do not expose the battery to heat, fire, or direct sunlight. Do not recharge, short-circuit, or open the battery. Dispose of the used battery in accordance with local regulations. |
Mounting Door Lock Air Battery for Glass Doors↑
Prepare the glass door as shown in the following picture:

Place the Door Lock Air in the designated position on the glass door:
![]() | The auxiliary latch must not engage with the strike plate. |


Insert the supplied 2 x AAA batteries into the device:

![]() | We recommend using lithium based batteries. |
![]() | CAUTION: There is a risk of explosion if the battery is replaced improperly. The replacement must only be with the same or specified type. Do not expose the battery to heat, fire, or direct sunlight. Do not recharge, short-circuit, or open the battery. Dispose of the used battery in accordance with local regulations. |
Commissioning↑
In delivery state, pairing mode will be active after the power supply has been established. This is indicated by the status LED flashing red/green/orange.
![]() | For Door Lock Air Inductive: The door must be closed during the pairing process to ensure that the device is powered via the inductive module. |
![]() | The Battery variant communicates via its own radio channel. Therefore, an NFC Code Touch Air (24 V), a Miniserver Compact, a Miniserver Go, an Air Base Extension, or a Tree to Air Bridge must be within Air range. |
Then follow the pairing procedure on the Air Interface.
To manually activate the pairing mode, remove the cover over the pairing button or the battery cover, and press the pairing button for at least 5 seconds.
![]() | For the Inductive variant: The door must be closed immediately afterward. |

Sensors↑
| Summary | Description | Value Range |
|---|---|---|
| Position | Current position of the door. Can be used with Door and Windows Monitor 1=closed 3=open 4=closed and unlocked 5=closed and locked 6=open and unlocked 7=open and locked 0=unknown/offline | 0...7 |
| Unlocked | Input is active when lock is unlocked | 0/1 |
| Unlocked by key | Input is active when lock is unlocked by key | 0/1 |
| Closed | Input is active when the door is closed | 0/1 |
Actuators↑
| Summary | Description | Value Range |
|---|---|---|
| Unlock | Lock is unlocked as long as this output is ON | 0/1 |
Diagnostic Inputs↑
| Summary | Description | Unit | Value Range |
|---|---|---|---|
| Online Status Door Lock Air | Indicates whether the device can be reached by the Miniserver. Diagnostics for Air devices Diagnostics for Tree devices Diagnostics for Extensions | Digital | 0/1 |
| Voltage Shutdown | Input is active when the device is offline, because of its supply voltage dropping too low. Possible reasons: Battery empty or disconnected from supply too long | Digital | 0/1 |
| Battery Low | This input activates when the battery level is <= 15%. The device only supplies values to this sensor when it is powered by batteries. | Digital | 0/1 |
| Battery Level | This sensor indicates the current battery level. If the device is externally supplied with 24v, the value of 100 is constantly shown. | % | ∞ |
Properties↑
| Summary | Description | Default Value |
|---|---|---|
| Monitor Online Status | If checked, you will be notified via System Status or the Mailer if the device is no longer available or goes offline. | - |
| Serial Number | Serial number of Air device. Automatic pairing can be enabled on the Air Base. Automatic pairing can be enabled on the Airbase for a set time. | - |
| Audible acknowledgement | Audible confirmation when door is opened or closed | - |
Safety Instructions↑
Installation must be carried out by a qualified electrician in accordance with the applicable regulations.