LOXONE CONFIG PUBLIC BETA CHANGELOG
LOXONE Config 17.1.8.4 - Beta 2
New
General
- Added the Wall Display 10″ device and function block.
- C7WT-I182: Intelligent Room Controller now provides display events for humidity and CO2.
Planning
- Added Touch Pure Display Tree and Air, including CO2 variants, to Project Planning.
UI
- Added Touch Pure Display UI support for Burglar Alarm and Fire and Water Alarm.
Improved
General
- Increased the number of supported UI elements for Touch Pure Display.
Usability
- Changed Touch Pure Display utilization to use a recommended soft limit of 100%, which can be exceeded.
- Function blocks can be added until the device-specific maximum is reached.
Fixed
Audio
- BG-I41193: Central Audio controls respond again to assigned music players.
Climate
- BG-I51870: Fixed the AC Unit Controller reactivating after being switched off by the Intelligent Room Controller.
General
- Fixed Touch Pure Display active light moods being shifted by one.
- Fixed incomplete favorites being transferred to the app Ambient Mode in Client Gateway systems.
- WA2-I132: Fixed the Managed Tablet configuration version not being updated after an update.
- BG-I51767: Fixed CO2 sensors being selectable for unsupported devices in the Alarm dialog.
- BG-I51930: Fixed Touch Pure Display inputs not working with Miniserver Gen. 1.
- BG-I48850: Fixed Trusted Intercom using an incorrect address for local-only trusts.
- BG-I51799: Fixed Touch Pure Display controls not being shown after deleting an entire group.
- BG-I51797: Removed custom icon options from the Touch Pure Display dialog.
- BG-I51801: Fixed the Touch Pure Display active moods event not handling non-visualized moods.
Planning
- BG-I51344: Added AC Control Tree and Hörmann Tree to Project Planning.
- BG-I51855: Rooms were not shown in the periphery tree after creating a project.
UI
- Fixed Touch Pure Display recovery after an ESD strike corrupted the LCD state.
LOXONE Config 17.1.7.24 Release Candidate
New
General
- Touch Pure Display Air & Tree
- Touch Pure Display Controller
Climate
- BG-I50664: IRC / AC history now records fan speed and airflow changes.
- Changes caused by the AC unit, for example Silent Mode or a manual selection on the unit, are now shown as coming from the AC Unit Controller.
- Fan speed and airflow changes made on the IRC are now logged as well.
- On the AC unit, fan speed and airflow changes forwarded by the IRC are now attributed to the IRC in its history.
Fixed
Audio
- BG-I49711: Audioserver Player no longer logs a “reset to default” history entry when a control preset/template is updated. The entry is now only recorded on a real RTD input edge.
- BG-I50654: Audio devices now show their room in the Device Status dialog.
- LOXONE radio history entry was incomplete. The station name is now added.
- LOXONE radios set as default room favourite when empty
- Soundbar can now be inserted in Config
- Soundbar: enhanced reconnect on Wi-Fi loss, added quality logging
- Soundbar: volume step size was not taken into account on volume change via TV’s remote
- BG-I51048: Wrong system status message when HDMI is not providing audio data
- HDMI: improved compatibility with some LG and Sony TVs
- Wireless Speaker: enhanced reconnect on Wi-Fi loss, added quality logging
- Wireless Speaker: boot time during network detection optimized
Climate
- Fan Speed “off” can no longer be selected for Silent Mode.
- BG-I49679: IRC: replacing a source (delete + add a different one) in a single source-assignment session is now applied correctly. Previously the slot kept the old source and the new one was dropped.
- BG-I49686: IRC override via input E, Comfort/Eco/Eco2, now stays active across operating mode changes (e.g. heating to cooling). Releasing the override restores the setpoint to the calendar temperature instead of leaving it stuck on the override value.
- BG-I49788: IRC +/- buttons now adjust the active comfort setpoint while a “Comfort until midnight” override is active on top of a Fixed Setpoint operating mode set via the input, instead of silently changing the hidden manual value.
- BG-I49793: AC Control unit no longer keeps running when only a single operating mode is enabled and the IRC requests the other direction. The unit now switches off instead of substituting an unrelated enabled mode.
- BG-I50211: IRC + AC: the “cooling/heating not available” hint caused by an AC pause timer now clears immediately when the pause ends, instead of lingering up to ~10 seconds.
- BG-I50365: AC Control did not restore the fan speed after disabling Silent Mode when the unit was controlled by an IRC. The unit now reverts to the previously defined fan speed, and the IRC’s Silent Mode override hint clears immediately.
- BG-I50380: IRC comfort temperature changes that would push the eco temperature beyond frost/heat protection are now ignored (eco follows comfort by a fixed offset).
- BG-I50694: IRC + AC: resetting the IRC no longer restores the fan speed in a way that can unintentionally start the AC unit without active demand.
- BG-I50707: IRC no longer shows the open door/window override in the app before the configured window-open delay has elapsed.
- AC Controller no longer keeps running or restarts with no demand when Silent Mode is disabled while the IRC is off or locked.
- AC Controller resumes correctly after the lock/off input is released. Fan speed, airflow direction and Silent Mode state are restored to what the room controller actually requests, instead of coming up at a wrong or stale value.
- Silent Mode is re-applied after an AC Controller reset. A fan speed picked in the app (which exits Silent Mode) is cleared by the reset, so the still-active Silent Mode input takes effect again.
- The room controller’s fan speed display in the app now stays in sync with the AC unit and is no longer stuck showing “Silent” or the previous speed after Silent Mode ends.
- The IRC and its Fan Coil / Central Fan Coil sources no longer get stuck reporting no demand after saving into the Miniserver, even with active heating or cooling demand. Recovery no longer requires nudging the room temperature.
- The IRC now clears its per-source heating/cooling outputs when a connected Fancoil turns off. Previously those outputs could stay frozen at their last value until a temperature change or a long timeout reset them.
- Picking an AC unit fan speed in the app while a door/window is open now also clears the door/window override on the IRC.
- Turning the IRC off in the app no longer logs a spurious “Heating activated” history entry.
- Turning an IRC off no longer leaves its AC unit and AC Central showing as active for about 10 seconds. The state now switches off immediately.
- IRC + AC: the room’s own delayed door/window override is no longer masked when the AC unit’s own door/window contact is toggled during the delay.
- A standalone Heating/Cooling Controller and HVAC-USA now report the correct “different mode selected” override on the IRC when the configured season differs from the room’s requested mode.
- A per-unit mode-mismatch override on an AC Controller is now attributed to the AC unit whose mode differs instead of to the AC Central.
- IRC + AC: a load-shedding override raised by an AC unit is now attributed to the unit itself instead of its AC Central.
- The “device offline” override now reports the executing AC unit that went offline instead of leaving the source empty.
- IRC now reports the correct block as the source of an override when driven by a Fancoil. Central-level reasons (insufficient demand, heating/cooling outdoor limit, forbidden heating/cooling mode, differing central mode) are attributed to the Central; a central lock reports the Central; a unit’s own Off-lock reports the unit.
- IRC now consistently reports a transferred heating/cooling ban as a “heating/cooling not possible” override instead of sometimes showing “central in a different mode” (single-mode room whose climate source sits in the opposite season).
- Fancoil Central: changing the outdoor temperature limits (heating/cooling forbidden thresholds) from the app had no effect. The limit parameters are now writable at runtime and applied immediately, matching the AC Central behaviour.
- BG-I50739: IRC history did not clearly describe the reaction to an open window
- BG-I51219: AC Control target temperature was reset to the default when the unit was switched off, and reset to 20° (instead of the configured default) after locking the block and saving to the Miniserver
- IRC now shows the AC unit’s “off”/reset override with priority over door/window, load-shedding and silent-mode overrides
- IRC-controlled Fan Coil fan-speed sync: the first manual fan speed picked after Auto was silently ignored, and switching to Auto could momentarily show Off
Devices
- NFC Code Touch Air new binary: 17.01.07.02
- Fix Air wakeup signal channel not applied correctly after update.
- Ceiling Light Air new binary: 17.01.07.02
- Fix Air wakeup signal channel not applied correctly after update.
- BG-I50771: Touch Flex: older configurations can now be exported and re-imported.
- BG-I51343: Fixed incorrect identify string in the context menu
- Smoke & Presence Detector Air/Tree
- SPD-T989: fire alarm detection mode is selectable again (Smoke & Heat / Smoke / Heat); existing installations are reset to the default “Smoke & Heat”
- SPD-T989: Smoke & Presence Detector Air/Tree dirty/faulty smoke chamber message now has its own title and describes the cause and cleaning steps
- SPD-T989: Smoke & Presence Detectors on the Fire and Water Alarm block keep sounding after the maximum alarm duration and are only silenced by an explicit user acknowledge (app button / device press); the function block and non-confirmable detectors still switch off automatically
- SPD-T989: during the pre-alarm phase only the Smoke & Presence Detector that actually senses fire sounds; the other detectors on the block stay silent until main alarm, and it can already be silenced by an acknowledge during pre-alarm
- Nano DI Tree
- BG-I49638: NanoDI doubleclicks not detected anymore after the update to 17.1.5.26
General
- BG-I50586: Created rooms are now visible in the tree after closing the Room dialog.
- BG-I50612: Operating mode “Simulation” is now set as Switch by default.
- BG-I50704: Live Learning: wireless speakers are now shown in search results.
- BG-I50836: Push notifications triggered by function blocks are no longer sent to unpermitted websocket connections.
- Editing properties (via context menu) of an empty, newly created page no longer uses the last selected page.
- Fixed an issue where no page was selected after closing the learning dialog.
- BG-I48575: No Modbus communication on 3-phase Energy Meter Tree
- BG-I48242: Energy Meter Tree – Modbus background looks like it is not communicating
- A Presence Controller’s presence output now auto-connects to the presence input
- R11-T80: Controls on different Miniservers can now exchange large data reliably
Lighting
- BG-I50579: Light Controller endless movement protection no longer stops after an NTP time update.
Plugin
- BMW CarData Integration new version: 0.0.54
- Fixed rapid exhaustion of the daily request limit on BMW accounts with more than one vehicle. Each vehicle now uses its own data container and a cached descriptor set, so a container rebuild costs a single request instead of ~27, and multiple vehicles no longer interfere with each other’s containers.
- Clarified that the daily request limit is per BMW account (shared across all vehicles), not per vehicle.
- Shows a clear, actionable message when the BMW CarData API is not activated, the Client ID is invalid, or the account is pending activation.
- The “request limit reached” message is now cleared automatically after a restart and after the next successful data request.
- No longer rebuilds the data container when the daily request limit is reached.
- The “CarData API not activated” message is no longer cut off.
- The “access denied” message now explains how to fix the issue (sign in as the vehicle’s main user and accept the CarData data sharing in the MyBMW portal).
- i4 (G26) charging is now detected correctly (recognizes the “CHARGINGACTIVE” status), so Charging and Remaining Charge Time update while charging.
- Cable Connected now reflects the actual plug state instead of only being inferred from charging.
- No longer triggers an automatic data request when saving the configuration or restarting while already authorized. The last known values are restored immediately after a restart instead.
- McpServer new version: 1.0.5
- Status overview now also reports the plugin’s own version alongside the Miniserver firmware version.
- Control states no longer occasionally come back empty right after a state query. An acknowledgement from the Miniserver could be mistaken for the values that followed it, silently dropping them; those values now always come through.
- Shades that report two position readings under the same value (roof windows, awnings) now return both when queried by either state name.
- Connections no longer get stuck behind a “rate limit” error after being connected a while; a dropped connection now recovers on its own.
- Connections no longer stop responding after a pause in the conversation. Every request is handled on its own, so the assistant keeps working without needing a restart.
- Stricter assistant clients can now connect. A command tool described one of its inputs in a way some clients rejected, dropping the whole connection. The input is now described so every client accepts it.
- Added a status warning when an older Remote Connect keeps changing the remote address (disconnecting remote AI assistants), advising you to contact your LOXONE Partner; sign-in now works when the Miniserver uses a custom HTTP port (previously every login attempt was declined unless the port was set back to 80).
- Segway Navimow new version: 1.0.2
- “No mower” system status messages are now of type information.
- Login token is now saved per plugin instance.
- Updated translations.
Stability
- BG-I47422: Fixed crash when converting a function block.
- BG-I50369: Fixed a crash when locating an unconfigured automatic rule from a system message.
- BG-I50999: Fixed Config crash after importing a Belimo template.
- Config no longer crashes while updating a Miniserver.
Usability
- BG-I50640: Numeric property edits confirmed with Enter now refresh dependent settings.
LOXONE Config 17.1.7.19 - Beta
General
- Touch Pure Display Air & Tree
- Touch Pure Display Controller
Climate
- BG-I50664: IRC / AC history now records fan speed and airflow changes.
- Changes caused by the AC unit, for example Silent Mode or a manual selection on the unit, are now shown as coming from the AC Unit Controller.
- Fan speed and airflow changes made on the IRC are logged correctly.
- On the AC unit, fan speed and airflow changes forwarded by the IRC are now attributed to the IRC in its history.
Fixed
Audio
- BG-I49711: Audioserver Player no longer logs a “reset to default” history entry when a control preset/template is updated. The entry is now only recorded on a real RTD input edge.
- BG-I50654: Audio devices now show their room in Device Status dialog.
- LOXONE radio history entry was incomplete. The station name is now added.
Climate
- Fan Speed “off” can no longer be selected for Silent Mode.
- BG-I49679: IRC: replacing a source (delete + add a different one) in a single source-assignment session is now applied correctly. Previously the slot kept the old source and the new one was dropped.
- BG-I49686: IRC override via input E, Comfort/Eco/Eco2, now stays active across operating mode changes (e.g. heating to cooling). Releasing the override restores the setpoint to the calendar temperature instead of leaving it stuck on the override value.
- BG-I49788: IRC +/- buttons now adjust the active comfort setpoint while a “Comfort until midnight” override is active on top of a Fixed Setpoint operating mode set via the input, instead of silently changing the hidden manual value.
- BG-I49793: AC Control unit no longer keeps running when only a single operating mode is enabled and the IRC requests the other direction. The unit now switches off instead of substituting an unrelated enabled mode. .
- BG-I50211: IRC + AC: the “cooling/heating not available” hint caused by an AC pause timer now clears immediately when the pause ends, instead of lingering up to ~10 seconds.
- BG-I50365: AC Control did not restore the fan speed after disabling Silent Mode when the unit was controlled by an IRC. The unit now reverts to the previously defined fan speed, and the IRC’s Silent Mode override hint clears immediately.
- BG-I50380: IRC comfort temperature changes that would push the eco temperature beyond frost/heat protection are now ignored (eco follows comfort by a fixed offset).
- BG-I50694: IRC + AC: resetting the IRC no longer restores the fan speed in a way that can unintentionally start the AC unit without active demand.
- BG-I50707: IRC no longer shows the open door/window override in the app before the configured window-open delay has elapsed.
- AC Controller no longer keeps running or restarts with no demand when Silent Mode is disabled while the IRC is off or locked.
- AC Controller resumes correctly after the lock/off input is released. Fan speed, airflow direction and Silent Mode state are restored to what the room controller actually requests, instead of coming up at a wrong or stale value.
- Silent Mode is re-applied after an AC Controller reset. A fan speed picked in the app (which exits Silent Mode) is cleared by the reset, so the still-active Silent Mode input takes effect again.
- The room controller’s fan speed display in the app now stays in sync with the AC unit and is no longer stuck showing “Silent” or the previous speed after Silent Mode ends.
- The IRC and its Fan Coil / Central Fan Coil sources no longer get stuck reporting no demand after saving into the Miniserver, even with active heating or cooling demand. Recovery no longer requires nudging the room temperature.
- The IRC now clears its per-source heating/cooling outputs when a connected Fancoil turns off. Previously those outputs could stay frozen at their last value until a temperature change or a long timeout reset them.
- Picking an AC unit fan speed in the app while a door/window is open now also clears the door/window override on the IRC.
- Turning the IRC off in the app no longer logs a spurious “Heating activated” history entry.
- Turning an IRC off no longer leaves its AC unit and AC Central showing as active for about 10 seconds. The state now switches off immediately.
- IRC + AC: the room’s own delayed door/window override is no longer masked when the AC unit’s own door/window contact is toggled during the delay.
- A standalone Heating/Cooling Controller and HVAC-USA now report the correct “different mode selected” override on the IRC when the configured season differs from the room’s requested mode.
- IRC + AC: a load-shedding override raised by an AC unit is now attributed to the unit itself instead of its AC Central.
- The “device offline” override now reports the executing AC unit that went offline instead of leaving the source empty.
- IRC now reports the correct block as the source of an override when driven by a Fancoil. Central-level reasons (insufficient demand, heating/cooling outdoor limit, forbidden heating/cooling mode, differing central mode) are attributed to the Central; a central lock reports the Central; a unit’s own Off-lock reports the unit.
- IRC now consistently reports a transferred heating/cooling ban as a “heating/cooling not possible” override instead of sometimes showing “central in a different mode” (single-mode room whose climate source sits in the opposite season).
Devices
- NFC Code Touch Air new binary: 17.01.07.02
- Fix Air wakeup signal channel not applied correctly after update.
- Ceiling Light Air new binary: 17.01.07.02
- Fix Air wakeup signal channel not applied correctly after update.
- BG-I50771: Touch Flex older configurations can now be exported/re-imported.
General
- BG-I50586: Created rooms are now visible in the tree after closing the Room dialog.
- BG-I50612: Operating mode “Simulation” is now set as Switch by default.
- BG-I50704: Live Learning: wireless speakers are now shown in search results.
- BG-I50836: Push notifications triggered by function blocks are no longer sent to unpermitted websocket connections.
- Editing properties (via context menu) of an empty, newly created page no longer uses the last selected page.
- Fixed an issue where no page was selected after closing the learning dialog.
Lighting
- BG-I50579: Light Controller endless movement protection no longer stops after NTP time update.
Plugin
- BMW CarData Integration 0.0.54
- Clarified that the daily request limit is per BMW account (shared across all vehicles), not per vehicle.
- Shows a clear, actionable message when the BMW CarData API is not activated, the Client ID is invalid, or the account is pending activation.
- The “request limit reached” message is now cleared automatically after a restart and after the next successful data request.
- No longer rebuilds the data container when the daily request limit is reached.
- The “CarData API not activated” message is no longer cut off.
- The “access denied” message now explains how to fix the issue (sign in as the vehicle’s main user and accept the CarData data sharing in the MyBMW portal).
- i4 (G26) charging is now detected correctly (recognizes the “CHARGINGACTIVE” status), so Charging and Remaining Charge Time update while charging.
- Cable Connected now reflects the actual plug state instead of only being inferred from charging.
- No longer triggers an automatic data request when saving the configuration or restarting while already authorized. The last known values are restored immediately after a restart instead.
- McpServer 1.0.5
- Status overview now also reports the plugin’s own version alongside the Miniserver firmware version.
- Control states no longer occasionally come back empty right after a state query. An acknowledgement from the Miniserver could be mistaken for the values that followed it, silently dropping them; those values now always come through.
- Shades that report two position readings under the same value (roof windows, awnings) now return both when queried by either state name.
- Connections no longer get stuck behind a “rate limit” error after being connected a while; a dropped connection now recovers on its own.
- Connections no longer stop responding after a pause in the conversation. Every request is handled on its own, so the assistant keeps working without needing a restart.
- Stricter assistant clients can now connect. A command tool described one of its inputs in a way some clients rejected, dropping the whole connection. The input is now described so every client accepts it.
- Segway Navimow 1.0.2
- “No mower” system status messages are now of type information.
- Login token is now saved per plugin instance.
- Updated translations.
Stability
- BG-I47422: Fixed crash when converting a function block.
- BG-I50369: Fixed a crash when locating an unconfigured automatic rule from a system message.
- BG-I50999: Fixed crash after importing a Belimo template.
- Config no longer crashes during Miniserver updates.
Usability
- BG-I50640: Numeric property edits confirmed with Enter now refresh dependent settings.
LOXONE Config 17.1 Release Candidate 2
New
MCP Server for Miniserver
- Added MCP Server plugin support.
- Allows integration of the Miniserver into AI tools.
- Available via Network Periphery.
- Added support for assistants to retrieve hourly outdoor weather forecasts in addition to current conditions.
FIAS PMS Integration
- Added user management support for check-in and check-out events.
- Added room information inputs for automation use cases.
- Added NFC-based access management.
BMW CarData
- Added BMW vehicle data integration for the Miniserver.
- Added one-time authorization via BMW account using the device code flow.
- Added vehicle signals for state of charge, electric range, mileage, door lock status, charging state, distance from home, and additional values.
- Added a manual polling trigger to fetch vehicle data on demand.
- Added support for up to 20 vehicles per Miniserver.
Segway Navimow Integration
- Added integration for Segway Navimow robotic lawn mowers.
- Requires Miniserver Gen. 2 with firmware 17.1 or newer.
- Supports up to 10 Navimow devices per Miniserver.
Room Grouping
- Added support for nested room groups with configurable icons and ratings.
- Added navigable group cards in the Rooms tab of the App.
- Added support for room favourites within groups based on room rating.
- Added group sorting by rating.
LOXONE radio
- Real music: 13 streams, updated daily — includes hits and evergreens across genres.
- Free and ad-free: no ad breaks and no licensing fees* — just music, uninterrupted.
- Legal and hassle-free: no need to worry about music licenses, even in commercial settings.*
- Ready to stream: via the LOXONE App, triggered by presence, time schedule, or manually.
General
- Added support for the Smoke & Presence Detector Air/Tree.
- A3D9-T2290: Simplified “Installation Location” handling.
- Removed for devices that act at their installation point.
- Kept for devices controlling elements in other locations.
- Existing projects remain unchanged.
- A3D9-T2171: Sauna Controller now supports DisplayEcho.
- BG-I47171: Automatic Designer now supports conditions for the Spot Price Optimizer.
- Reworked the Getting Started wizard UI.
- Implemented the new DockWidget system for the Property Window, Monitors, and Trees.
- R1701-T132: Improved SD card formatting performance by writing files directly to the SD card.
- R1701-T202: Added a new endpoint for service reachability health checks.
- FS1-T170: Added the RSSI RDC value in Air Diagnostics and Air Mesh.
- FS1-T141: Added automatic Airbase-RDC channel configuration when adding RDC devices.
- BG-I49917: Updated the description of the default alarm in the Alarm Clock.
Access
- Intercom: Added the “Doorbell Ring Preview” setting.
- Controls whether the app shows a still image or live video when the doorbell rings.
- Still image is the default.
- The still image captures the moment the doorbell was pressed.
- Requires app support.
Diagnostics
- Added an option to save Health Check and Device Diagnostics results as a PDF report.
- BG-I48823: Health Check result messages are now colored based on severity.
Lighting
- Added LC5–LC8 light circuit inputs to the Lighting Controller.
- Autoprogramming: created Light Controller moods now get a matching icon.
Audio
- R1701-T111: Added a CPU temperature diagnosis input for the Audioserver and connected audio devices.
Planning
- Added new Leaf Tree/Air articles.
- Added automatic calculation for Leaf ventilation.
- R1701-T78: Added the room type “Outdoor Area”.
Energy
- BG-I47277: Added the Peak Load Manager.
- Added the output “Available Power Peak” (ApPeak).
- Starts with MaxTp at the beginning of the interval.
- Gradually decreases to meet the power budget MaxP.
- Load Shedding now uses ApPeak for calculations.
- Input Gpwr can now add PV export power to the Ap and ApPeak outputs when negative.
Energy Flow Monitor
- Added current total consumer power output.
Climate
- BG-T4902: Intelligent Room Controller now automatically adapts the comfort range for heating-only or cooling-only capabilities.
Usability
- R1701-T1: Added automatic naming for selected function blocks using the room name.
- Applied on creation.
- Applied when the room name changes.
- Applied when the room assignment changes.
- Converted old programs accordingly.
- Device Status now shows the device IP/address in a new Info column.
- Migrated the Alarm Clock dialog to the modern Qt interface.
- Migrated the Room and Category dialog to the modern Qt interface.
- Migrated the State Text dialog to the modern Qt interface.
- Added support for deleting empty rows.
- Improved column sizing and tooltips.
- Improved the Miniserver connection workflow and credential handling.
- Added support for selecting local or external connection modes.
- Added project context to keychain entries.
- Preserved passwords when switching users.
- Decoupled project keychain usage from project management and connection handling.
- Added My Miniservers for Miniserver-specific credentials.
- Added My Credentials for reusable credentials independent of a Miniserver.
- Added access to My Credentials from the Connect dialog.
- Added support for credentials that are not tied to a specific Miniserver serial number.
- Credential selection now only fills username and password and leaves Miniserver addresses unchanged.
Devices
- Added Device Telemetry.
- Sends device diagnostics information to LOXONE.
- Can be activated with the “Enable Device Logging” document setting.
- A remote server defines which device types or serial numbers are monitored.
- Monitored devices send cyclical diagnostic information to the Miniserver.
- The Miniserver forwards the data to a cloud server.
- Communication is encrypted and does not contain sensitive data.
- Added Wallbox Air/Tree binaries.
- Added Touch Pure Flex Gold variants.
- Added AC Control Tree, Hörmann Tree, and Modbus Tree.
- Updated Air Master binaries.
- C7WT-T414: Added Air Base adaptation for Large Update.
- Added a new RDC wake-up channel and RDC wake-up improvements.
- Added Touch Controller support for Touch Pure for Nano.
- Added support for the Touch Controller IQS7222C.
- Added support for Nano IO and Nano Dimmer.
- FS1-T175: Device Status now shows an unknown battery state.
- Door Lock Air 17.01.06.03:
- Added support for battery-operated Door Lock Air devices.
- Improved Air wakeup functionality.
- NFC Code Touch Air 17.01.06.22:
- Implemented Air wakeup signal routing.
- Ceiling Light Air 17.01.06.23:
- Implemented Air wakeup signal routing.
AC Control Tree
- Added a communication watchdog that triggers a reset after communication loss.
- Added logging of the last communication between AC Control and the AC unit before reboot.
- Added status messages when communication between AC Control and the AC unit is not possible.
- Added status messages showing the current AC error code for supported manufacturers.
Plugins
- Fronius Plugin 1.4.27:
- Added verification of AC output power limits.
- Added a notification if control is non-functional.
- Updated documentation.
- Improved error handling and system stability.
- Plugin Framework:
- Added support for SVG icons in the ribbon and device status panel.
Stability
- Reworked the Miniserver Health Check to provide additional diagnostic information.
Fixed
General
- BG-I43835: Automatic rules now reactivate correctly after a restart or update.
- BG-I48228: Property window now shows “Device Type” when an IO of a device is selected.
- BG-I48284: Central Audio OFF input negation now blocks only inputs and not AP.
- BG-I46736: Miniserver Client is no longer incorrectly reported as offline.
- BG-I44570: DispPc from a switch no longer blocks the OFF input.
- BG-I48149: Central inputs now work correctly when the user interface password is enabled.
- BG-I48161: Fire & Water Alarm now triggers correctly for negative maximum temperature values.
- BG-I47783: Text Generator <time.date> no longer shows an incorrect date after 22:00.
- BG-I43675: Wallbox Air NFC Code Touch Tree update now completes correctly.
- BG-I47517: Intelligent Room Controller history now differentiates heating and cooling preparation phases.
- BG-I47516: Adapted the severity description for custom system messages.
- BG-I47333: Intelligent Room Controller statistics now show the correct unit in the app.
- Energy Flow Monitor meters are now shown correctly in regular visualization.
- BG-I47968 / BG-I47998: Removed the error code from the Client/Gateway error message.
- BG-I47999: Fixed a blank error message when entering Client/Gateway mode with different credentials.
- Fixed a race condition while waiting for the logon response from the Miniserver.
- Fixed HTTP requests from Config to the Miniserver not using Basic Auth headers.
- BG-I47321: Fixed Miniserver replacement with factory credentials and HTTPS redirect enabled.
- BG-I47249: Miniserver no longer queries register.loxonecloud when Remote Connect is disabled.
- BG-I47677: Tabs are now escaped in device status messages.
- BG-I46915: Fixed the language mismatch warning reappearing after saving to the Miniserver in the same session.
- BG-I47939: Fixed an incorrect message box dialog size in some cases.
- BG-I47971: Fixed action enablement for unregistering all push devices.
- BG-I47907: Object configuration dialog can no longer be resized below its minimum size.
- BG-I47877: Property window read-only text editor no longer overlaps property labels.
- BG-I47865: Fixed the selection update when editing an object by double-click.
- BG-I47862: Fixed a Property Window repaint issue after the Help View was opened.
- BG-I47791: Removed the “Insert Extension” action from the “Tree Turbo” ribbon context panel.
- BG-I48047: Exosphere projects are now appended instead of prepended to the project list.
- BG-I47940: Quick Access panel no longer hides actions after opening a project.
- BG-I48138: Managed Tablet setup code dialog is now positioned correctly.
- BG-I47693: User group “Nobody” is no longer visible in the multi-edit dialog when editing all user groups.
- Fixed an incorrect character in the SKY language menu.
- BG-I47375: Improved authentication error def.log entries.
- BG-I47897: Fixed CLxStringU comparison operators performing pointer comparison instead of string comparison.
- BG-I46609: Fixed interfering tooltips in the Property Window.
- BG-I47420: Fixed combobox rendering in table/tree views on Windows 11.
- BG-I46953: Update notification panel now shows buttons correctly.
- BG-I47465: Fixed an incorrect time editor value when the AM/PM format was used.
- BG-I47440: Entire row is now selectable in Tree Views.
- BG-I43804: Added a button to abort an ongoing Miniserver connection attempt.
- BG-I47492: Fixed a possible crash when switching the actor type of a DALI device.
- BG-I47753: Fixed an SD format dialog failure when “overwrite data” was selected.
- BG-I47429: Fixed the HVAC Controller Y2 output description for “Heat Pump with Electric Backup”.
- BG-I47143: App WSP no longer appears in Tree Turbo search.
- BG-I47343: Teaching in a battery-powered Presence Sensor Air no longer shows inputs from a 24V device.
- BG-I47443: Repeating Auto Config no longer removes backup mode.
- BG-I47538: Gate with opening/closing duration set to zero no longer fails to stop.
- BG-I46911: Fixed chunked HTTPS response handling for Virtual HTTP Input.
- R20-I20: Valve Actuator Tree status LEDs can now be disabled.
- BG-I46277: Added a new custom message box implementation to fix layout issues.
- BG-I47398: Fixed Unicode conversion for Rooms/Categories in the ribbon.
- BG-I46760: Lighting Controller now shows “Not fully configured” when no settings are configured.
- BG-I46584: Stereo Output 1 is no longer always named as Audioserver when connected to the AP block.
- BG-I46419: Text Generator now shows the correct time in Live View.
- BG-I46895: Spot Price Optimizer now shows CHF instead of EUR for CH markets.
- BG-I46921: Audio Player function block now displays assigned devices correctly.
- BG-I44547: Fixed negated outputs and switches in Live View for affected outputs.
- BG-I46957: Auto Config no longer replaces a custom light mood.
- BG-I47041: Planning Tool now includes missing Signal White devices.
- BG-I46223: Fixed LED blink position calculation with installation and Tree branch sorting.
- BG-I47539: IRC fan speed presence setting now has a name in expert mode.
- Updated outdated icons and colors.
- BG-I47438: Velvet White Touch Pure Flex now shows correct inputs after updating from the Configurator.
- Users with update rights can no longer change the update level.
- BG-I47216: Monitoring online status can now be disabled for Modbus TCP devices.
- BG-I47417: Fixed incorrect reference names for TPF on Intercom.
- BG-I48288: Fixed Air Diagnostics behavior.
- BG-I48306: Fixed unknown devices shown in Air Diagnostics.
- BG-I47507: Existing network devices are now shown in the search dialog when the hostname uses a local TLD.
- BG-I48437: Download Exosphere project dialog now closes automatically in all cases.
- BG-I47853: Save template ribbon action is no longer displayed for unsupported selected devices/objects.
- BG-I47832: Audioserver is no longer created as a Wireless Speaker when generating a part list.
- BG-I48067: Fixed German grammar in audio device configuration.
- BG-I48695: Managed Tablet drag and drop now works.
- BG-I48818: Irrigation block now saves time settings correctly on first change.
- BG-I48950: Fixed KNX Extension group address count above 500.
- BG-I48085: IRCs now display values for valve actuators on outputs connected to FCFC or FCC.
- BG-I48800: Nano 2 Relay Tree no longer shows current flow when set to shading type.
- BG-I48741: GETINPUT now returns connected IRC2 humidity and CO2 input values.
- BG-I47101: Sequence Controller no longer shows an incorrect popup about changes.
- BG-I48934: Automatic Designer/Scenes no longer shows charge mode actions for a managed wallbox.
- BG-I42982: Presence parameter TWarn is now validated against Pet.
- BG-I45729: Presence acoustic reactivation is prevented while control is locked.
- BG-I48528: App Control URL setting now includes a description for universal links.
- BG-I49283: File upload timeout increased to 2 minutes for Miniserver Gen. 1 upload failures.
- BG-I48460: Backup files in the Project Backups dialog are now sorted correctly by date.
- BG-I47928: AutoConfig now switches to the Periphery tree when showing unassigned peripherals.
- BG-I47131: System status date now uses the system language.
- BG-I48949: Periphery tree online indicator now shows an “Online” tooltip.
- BG-I48238: Editing the name in the Property Window now sets the document modified flag correctly.
- BG-I48065: Project Backup dialog now shows the creation date correctly.
- BG-I48771: Opening the Miniserver update dialog no longer switches the selected ribbon category.
- BG-I48622: Editing after copy and paste now targets the correct function block.
- BG-I48596: Fixed an incorrect column layout in the New Miniserver page table.
- BG-I48516: Connecting from the New Miniserver page table now prefills the IP address.
- BG-I48829: Added the missing AC Control monitor action to the context ribbon.
- BG-I48066: Fixed incorrect or truncated project backup folder names when project names contain dots.
- BG-I48791: Fixed missing dialog buttons in some cases.
- BG-I47858: Corrected tooltip behavior in the Property Window.
- BG-I47609: Message boxes are no longer automatically closed by the Exosphere loading dialog.
- BG-I48984: Fixed an incorrect ribbon context panel for the Touch caption under Nano Dimmer Air devices.
- BG-I48155: LiCo buzzer history no longer creates two entries for short pulses.
- BG-I48348: AC Unit Controller forward thetaC is no longer visible when AC Control is not used.
- BG-I48366: API connector reference can now be deleted from the Fan Coil Unit Controller.
- BG-I48365: Deleted API connector references are no longer shown as connected.
- BG-I48148: Formula module no longer incorrectly shows “invalid formula” after updating to version 17.
- BG-I47861: Updated nomenclature for Automatic Shading outputs in Automatic Designer.
- BG-I48048: Update dialog no longer offers to load the project from the Miniserver when the local project is newer.
- BG-I48100: Statistics CSV export now includes units in the column headers.
- BG-I48107: Schedules from presets now appear in other projects.
- BG-I48254: Fixed the IRC block default fan speed when a Fan Coil Unit Controller is connected.
- BG-I48469: MinMax V1 now compares with V2 when not connected.
- BG-I48649: SPD Temperature Send Cycle setting now accepts zero as “Off”.
- BG-I48563: Text Generator output now updates time.time.
- Fixed a crash when saving to the Miniserver with child network devices.
- BG-I47510: Managed Tablet no longer changes brightness after an update.
- BG-I47383: Modbus TCP receive timeout system message is now set to historic when sensors are removed from the program.
- Fixed download of new plugin versions not working. Regression in 17.1.5.28.
- BG-I34091: Fixed a DALI device learned as the 64th device on a fully populated extension taking broadcast address 255.
- BG-I47938: User Management API NFC tags and access codes are no longer editable for trusted users.
- BG-I48156: Fixed status block icon colors from older projects not being converted to the current green.
- BG-I49384: Sequence Controller now supports == as the equality operator while keeping = compatible.
- Fixed a Modbus Sensors warning when a property value was adapted because the maximum number of fast sensors was reached.
- BG-I47997: Fixed Extension Search in the app not showing Dimmer and 1-Wire Extensions.
- Fixed empty schedules after RTD.
- BG-I49371: Sequence Controller now uses outputs S and TQ when adding custom loggers or trackers.
- BG-I47851: Touch Pure Flex API display text no longer switches off after changing a favorite.
- BG-I49429: Managed Tablet green banner can now be turned off in the app.
- BG-I48167: Quick Search window no longer stays open for affected dialog actions.
- BG-I47130: Firmware packages dialog no longer shows an empty entry in the configuration dialog.
- BG-I49048: Editing a name in the Property Window now immediately updates the control in the view.
- BG-I49166: Fixed Ribbon action visibility states not updating in some cases.
- BG-I49142: Function block IO description tooltip width is now limited.
- BG-I48866: Imported Belimo templates now appear in the popup menu list in all cases.
- BG-I49090: Restored Memory Flag delay parameter visibility and independent operation.
- BG-I49469: Central dialog now uses the correct “Display Name” column title.
- BG-I49772: Fixed a configuration lock-up when renaming a room.
- Fixed optional string settings with regex validation not being clearable.
- Fixed the Category Caption name being lost when closing the Room/Category dialog.
- Disabled updates for invalid Nano 2 Relay and Valve Actuator Tree versions.
- Fixed drag-and-drop handling where API actors and additional actors could be added to the wrong page.
- Fixed a potential telemetry-related memory leak.
- BG-I48467: Fixed incorrect negative values for signed 64-bit Modbus TCP sensors.
- BG-I48281: Fixed Fan Coil Unit Controller updates to the IRC OFF input.
- BG-I47911: Fixed inserting a Text Input into another Miniserver page for Network Intercom.
- BG-I48321: Fixed AC Controller receiving target temperature from IRC after being unlocked.
- BG-I48983: Alarm-triggered shading movements now include the alarm source in History.
- Quick Search popup is now displayed above dock widgets.
- Fixed missing save indication after inserting plugins requiring device learning.
- Fixed Config becoming unresponsive when opening the Room/Category dialog.
- BG-I49492: Statistics using “Every change (expert)” no longer create duplicate entries.
- BG-I49893: Fixed editing of Automatic Shading Rd parameter values via Property Window buttons.
- BG-I49616: Health Check dialog is now minimizable.
- BG-I49556: Added the missing editor for the Runtime Counter Maintenance parameter.
- BG-I49315: Clicking an empty page now resets the selected ribbon panel.
- BG-I49178: Backspace key now supports deletion in all locations where Delete was already supported.
- BG-I49773: Fixed mixed-up actions in the Quick Access panel.
- BG-I49892: HOME tab is now selected correctly when starting the Getting Started Wizard.
- BG-I49883: Room/Category dialog no longer appears unresponsive when deleting entries.
- BG-I49884: Newly created categories are now automatically selected when created from the Property Window.
- BG-I49918: Fixed missing prefilled user interface names in the Room/Category dialog on startup.
- BG-I49761: Custom colors selected in color dialogs now persist across Config sessions.
- BG-I50020: Fixed inconsistent button arrangement in system messages.
- BG-I50021: Added missing maximum device count text in Tree Turbo captions within the Periphery tree.
- BG-I49983: Fixed API connector drag-and-drop behavior when switching pages during insertion.
- BG-I48985: Statistics configured as “Each change (max. 1 per minute)” now flush suppressed values at the next minute boundary.
- BG-I50080: Fixed missing translations for system variables.
- BG-I50269: Added a delay to DNS health checks to prevent failures during the first run.
- BG-I50361: Added a minimum size for scrollbar handles in large views.
- BG-I49967: Fixed cut-off button text in the Miniserver state panel for some languages.
- BG-I49754: Fixed missing log entries in Device Diagnostics for certain devices and cases.
- BG-I47788: Fixed an issue where only one undo step was available in larger projects.
- Fixed ribbon action and button texts not updating correctly for rooms and categories in all cases.
- BG-I49623: Ribbon popup panels now close correctly after clicking or triggering an action.
- BG-I50237: Fixed automatic branch renaming after switching back from Tree Intercommunication to Link.
- BG-I48320: Fixed an incorrect “max count reached” message when inserting a Modbus template on a Modbus TCP server.
- BG-I49366: Multi-selection setting editors now update tree views after setting writes in all cases.
- BG-I49501: Fixed a missing linked object indicator on function blocks after copy and paste.
- BG-I49403: Burglar Alarm history now shows whether Window Handle Air was triggered by vibration or opening.
- BG-I49302: AC Central Controller mode changes are now displayed in Config.
- BG-I49041: Fixed Stereo Extension system temperature placement when the channel was already placed.
- BG-I48943: Fixed Thermal Solar Controller pump stopping too early.
- BG-I48790: Fixed incorrect Hz calculation for the Pulse Counter F input.
- BG-I49849: Fixed painting issues in the shared multiplicator settings dialog after editing.
- BG-I49955: Fixed very large projects failing to download or open from Exosphere.
- BG-147707: Fixed Ping block unlocking when not connected to Config.
- BG-I46655: Fixed the warning message device count for the Wallbox Air Tree Extension.
- BG-I49721: Replaced Tree Extensions are now searchable in Live Learning.
- BG-I49586: Added a LOXONE Config warning for Gen. 1 Miniservers before an update when memory is low.
- BG-I50067: Current time now updates while simulation is active.
- BG-I49072: Fixed time handling in AM/PM format in Simulation and the Property Window.
- BG-I50086: Trust periphery tree now uses the corresponding Miniserver type icon.
- BG-I50048: Floating Property Window now considers multi-selection in all cases when opened.
- BG-I50142: Command Recognition dialog now auto-scrolls to the found result.
- BG-I49379: Fixed the wrong configuration dialog opening when an intercom caption was selected.
- BG-I50049: Fixed Air Diagnostics view positioning on diagnosis startup.
- BG-I50139: Fixed color picker dialog positioning when opened from table views.
- BG-I50143: Floating Property Window now activates correctly after opening.
- BG-I49851: Block names no longer change when cancelling creation of a new room while editing multiple blocks.
- Fixed a Config crash when right-clicking a room group.
- BG-I49930: Virtual Input UDP default value handling now allows values outside the min/max range when validation is disabled.
- Fixed an invalid Tesla plugin signature that caused a redownload on every restart and increased Config startup time.
- Category is no longer a fixed column in the multi-edit dialog.
- Fixed LOXONE Config being unable to start the SD Format Tool when the Windows runtime libraries are not installed.
Diagnostics
- BG-I49871: Health Check device runtime is no longer reset incorrectly for EnOcean, Relay, and RS485 Extension hardware version 2 when clicking “Reboot devices”.
- BG-I49871: Expanded the tooltip description for runtime estimation of older devices when hovering over device runtime.
Climate
- BG-I46532: Heating and Cooling Controller in a Gateway Client no longer switches to OFF when saving to the Miniserver in affected cases.
- BG-I47803: Fixed swapped theta LimC and theta LimH positions in the app.
- BG-I48082: Fixed incorrect Ha and Ca input values for FCC, FCFC, and FCCc.
- BG-I47766: IRC is no longer shown as actively heating when heating is unavailable.
- BG-I47513: IRC2/HCC no longer creates a continuous overheating request from a pulse on Eh.
- BG-I46613: Heating and Cooling Controller now transfers the heating/cooling block when Otm is set by logic.
- BG-I45992: IRC now starts the AC Controller correctly when using all configured sources.
- BG-I47724: AC Unit Controller now becomes active again after being locked via the OFF input.
- Intelligent Room Controller no longer shows an invalid fan speed on input or in the app when using multiple AC Unit Controllers.
- BG-I42067: Heating and Cooling Controller no longer enters an invalid operating mode when input changes while control is locked.
- BG-I48837: Fan Coil Central Controller now prepares separate thresholds for the app.
- AC Unit Controller can now be switched off in standalone mode.
- Fan Coil Central Controller now sets the capability bitmask.
- Intelligent Room Controller now sets cooling capabilities for Fan Coil Unit Controllers.
- BG-I48341: Intelligent Room Controller now adds the connection bit to the target temperature input.
- BG-I48293: Outdoor temperature no longer remains stuck on the Fan Coil Central Controller.
- BG-I47967: FCCc now shows correct information in the app when Otm = 0.
- BG-I47881: FCC, FCFC, and FCCc abbreviations are now differentiated.
- BG-I46496: Up/Down arrow in IRC Air control now reacts correctly.
- BG-I48477: Copied ACc no longer keeps the IRC connection when it should not be present.
- Intelligent Room Controller now forwards fan speed changes to the AC Unit Controller correctly.
- Fixed AC Unit Controller not turning off when fan speed is set to “Off”.
- BG-I49298: AC Central Controller now shows connected Room Controllers.
- BG-I49219: Changing fan speed via IRC or app now ends Silent Mode.
- BG-I48082: Fan Coil and Central Controllers now show states Ha and Hc correctly in Live View.
- BG-I44119: Fixed Leaf Tree not working after a Miniserver restart. The program must be saved to the Miniserver again after the update.
- BG-I49595: Bedroom automatic comfort timer end time now runs until 12:00 instead of 08:00.
- BG-I49598: Heating and Cooling Controller mode is no longer pre-selected when added to a project.
- A3D9-T1144: SOT is now ignored when at least one IRC is below frost protection temperature.
- BG-I46128: IRC no longer remains in Building Protection after disabling Away Mode.
- BG-I48208: AutoConfig no longer raises inactive CoolComfort temperature for heating-only rooms.
- BG-I49572: Fixed IRC presets containing additional settings.
- BG-I47866: Fan Coil Central Controller rooms are no longer shown in the app.
- BG-I48454: IRC no longer starts cooling preheating for fixed heating setpoints that were already reached.
- BG-I49719: AutoConfig now transfers the heating and cooling ban to IRC created with CCo.
- BG-I50141: OFF mode set by calendar is now sent to the app.
- BG-I49677: Deprecated heating and cooling period defaults are no longer created and undeletable.
- BG-I49791: IRC target temperature input is no longer ignored in fixed setpoint mode.
- BG-I49925: IRC no longer switches to comfort mode until midnight when Silent Mode is triggered from a connected AC Unit Controller.
- BG-I49462: AC Unit Controller default fan speed and airflow are now applied after switching on when fan speeds were removed.
- BG-I49497: AC Controller Tg API input now works after the IRC connection is removed.
- BG-I48833: AC and IRC fan control no longer stays off after saving to the Miniserver.
- BG-I50337: IRC no longer shows the Heatprotect system message when no cooling capabilities are present.
- BG-I50128: AC no longer turns on while the OFF input is active.
- BG-I49439: AC Control on a Room Controller now shows the open door/window pause reason without delay.
- BG-I49548: Extended overrides for AC and Fancoil to their Unit and Central Controller.
- BG-I49548: IRC now reports a heating/cooling forbidden override when an energy source prohibits the requested mode.
- BG-I49548: AC unit mode changes now refresh the room controller immediately.
- BG-I49548: Added an override when outdoor temperature is beyond the configured heating/cooling limit.
- BG-I49548: Added an override when the room requests a disabled heating or cooling mode on the AC unit.
- BG-I49548: Override entries now report the UUID of the causing block.
- BG-I49548: Locked AC unit is now reported separately from a switched-off unit.
- BG-I49548: Corrected reporting level and severity of door/window, lock, and mode-mismatch overrides.
- BG-I49679: IRC source replacement within one source-assignment session is now applied correctly.
- BG-I49715: IRC no longer disables an independently wired heating/cooling source on a generic valve output when AC Central Control changes seasonal mode.
- BG-I49894: IRC +/- buttons can no longer lower a fixed setpoint below frost protection or above heat protection.
- AC Unit Controller permanent-off lock no longer puts the connected IRC into a fixed setpoint until midnight.
Energy
- Energy Flow Monitor residual values are now shown for sub-meters.
- BG-I48272: Meter reading offset no longer leaks into day/week/month/year statistics.
- BG-I48053: Fixed Energy Manager calculation with minimum runtime during ramp-up.
- BG-I48275: Restored the Type column position in the Energy Flow Monitor dialog.
- BG-I48112: Fixed output names in the Energy Manager when more than two outputs were connected.
- BG-I48285: Meter statistics graph now carries the last recorded value forward instead of showing zero.
- BG-I49008: Spot Price Optimizer now calculates the cheapest hours for minimum runtime correctly.
- Fixed Energy Manager configuration dialog column sizing.
- Car Charger device address settings now hide the /dev/udp prefix and restore it automatically when required.
- BG-I50202: Statistics are now disabled after a block is removed from the Energy Flow Monitor.
- Fixed Energy Manager target power reduction when lower-priority loads were still blocked by minimum runtime.
- BG-I44736: Fixed different values and ratios in annual and total energies in the Energy Flow Monitor.
Lighting
- BG-I48166: Fixed DMX brightness drop in the CW/WW mixing range.
- BG-I49310: Improved Light Controller history description for blocked presence automatic due to an active mood.
- BG-I50071: Fixed LiCo remanence when using the LC input.
- BG-I48956: New DALI Extensions now default the lamp state update cycle to 600 seconds.
- BG-I49059: Fixed color mode retention when the brightness slider is set to zero.
- BG-I40453: Fixed Spot Fading Time being ignored for small fading differences.
- BG-I45144: Fixed Learning Dialog spot behavior causing “construction site light”.
Shading
- BG-I49900: Fixed Shading Period Calculated History shown after reboot.
Mailer
- BG-I50149: Added missing user notification after SMTP retries are exhausted.
Access
- BG-I50224: Fixed NFC learn webservice discovernfc failing immediately on the first attempt due to a stale learn result.
Audio
- New equalizer allows more precise control of single bands.
- BG-I48313: Extension LED no longer remains orange blinking.
- BG-I47761: Audio Player now sends volume configuration correctly in affected gateway constellations.
- BG-I47992: Fixed an incorrect “Project modified” notification when closing a dialog without changes.
- Fixed Master/Client Speaker audio dropouts.
- Fixed Wireless Speaker update progress reporting.
- Event volumes slightly increased to match playback volume.
- Fixed Wireless Speaker static IP configuration.
- Fixed Wireless Speaker DHCP hostname registration.
- Fixed Wireless Speaker Bluetooth fallback when WiFi is unavailable.
- Fixed race conditions and crashes related to Audioserver playback, AirPlay, and Bluetooth handling.
- BG-I48176: Source changes are now promoted correctly among stacked devices.
- BG-I49201: Fixed an incorrect blink state on the Audioserver.
- Bluetooth connection to muted player groups no longer starts all players in unsupported cases.
- Bluetooth connection to non-grouped players now works.
- BG-I49076: Wireless Speaker now shows system temperature.
- BG-I49237: Device Status commands are now sent to the correct device.
- Live Learning now supports replacing a Wireless Speaker.
- BG-I48765: Device Status now shows the correct icon for Miniserver Compact.
- BG-I46916: Tree Turbo devices learned via the app are now shown as online in the tree.
- BG-I47646: Audio Player now shows the correct history message when presence is active and playback is paused.
- Fixed Stereo Extensions in split mode not working after an EQ revert.
- Equalizer reverted to old implementation and loudness was removed.
- BG-I47431: Audioserver now reconnects immediately when the secure session is lost.
- Fixed a crash caused by a library.
- Fixed Spotify “Account not premium” error message for affected accounts.
- BG-T5148: Added a cover art minification option for Room Favourites.
- BG-I49797: Removed unnecessary event loading on WebSocket connection.
- BG-I49809: Fixed invalid Room Favourite IDs being set via API.
- BG-I49688: Fixed playback issues when adding multiple Wireless Speakers to one player.
- Fixed incorrect Audioserver LED states shown in Config.
- Fixed Spotify room favorites not starting in some grouped environments.
- Fixed Spotify volume transitions when switching between Spotify and TuneIn.
- BG-I50068: Fixed Spotify default account selection after migration to the new eSDK.
- BG-I50148: Fixed Spotify playback issue on presence and incorrect playlist selection.
- Fixed Room Favourite priority handling where the Player selected Room Favourite ID 1 instead of the first Room Favourite.
- Fixed RTD not disconnecting Spotify Connect sessions.
- BG-I49360: Fixed Music Extension appearing offline after an Audioserver update until the firmware update completed.
- BG-I49401: Fixed autogrouping issues when audio players were inside a group.
- Fixed an issue introduced in 17.1.6.18 that prevented proper updating.
- BG-I43390: Changing the Audioplayer preset in Config now triggers changes on the Audioplayer.
- BG-I49490: Fixed diagnostic inputs of a Stereo Extension not being insertable when its audio output was already used.
- Fixed Spotify Connect issues on Miniserver Compact and Stereo Extensions.
- Wireless Speaker now gathers network time correctly when not paired with a Miniserver.
- BG-I50235: Fixed USB stick folders not being recognized.
- BG-I49711: Audioserver Player no longer logs a “reset to default” history entry when a preset/template is updated.
- BG-I50366 / BG-I50075: Fixed unintentional start of players when grouped and Spotify is selected on a single player.
- Local Audioserver players are no longer shown offline until the next service restart or save to the Miniserver in rare cases.
- Fixed Audioservers not being updateable and added the missing update path with a proper message.
Devices
- Touch & Grill now shows the correct battery value outside the function block.
- BG-I47768: Fixed volume thresholds graph after reset.
- BG-I45340: Tree now shows devices available for pairing when already paired on another branch.
- BG-I45162: Valve Actuator Air/Tree Gen. 2 start position detection can now be disabled.
- BG-I46362 / BG-I46639: Valve Actuator Air/Tree Gen. 2 devices now open fully.
- BG-I47995: Live Learning no longer shows replaced devices again after restarting search.
- BG-I40274: Leha shading now works reliably.
- Updated Nano Motor Controller Air/Tree binaries to 17.01.05.11.
- Telemetry is no longer incorrectly reactivated.
- BG-I45000: Fixed NFC behavior when two different NFCs are connected to one Anfc.
- BG-I45020: Fixed an incorrect popup when inserting T2AB to a Wallbox Air.
- Touch Tree, Touch Pure Tree, and Touch Pure CO2 Tree now respond reliably to touches.
- BG-I46364: Touch Pure Air backlight actor is removed correctly when the device is battery-operated.
- Updated Power Supply and Backup binary to 17.01.04.28.
- BG-I25399: Fixed device reset during TechReport webservice polling.
- BG-I27829 / BG-I33447 / BG-I39476: Fixed false “Backup active” and “Fuses blown” in supply-only mode on mains loss.
- Updated Smoke Presence Detector Air/Tree EU binaries to 17.01.05.07.
- BG-I48845: Volume thresholds dialog on the Presence Sensor no longer triggers auto-connect that logs out other users.
- Touch Pure Flex input blocks placed on the program page now refresh their name after button reassignment and configuration import.
- Updated Presence Sensor Tree binaries.
- BG-I45109: Fixed Presence Sensor keeping presence after a power reset.
- BG-I43936: Fixed Presence Sensor not blinking out of the box.
- Updated Shading Actuator Air binaries.
- BG-I40593: Fixed end position setting “Both directions” staying active for only about one second.
- Updated Nano DI Tree binaries.
- BG-I44616: Fixed Nano DI Tree reliability after a power-on reset.
- Fixed the first input sometimes being shown as LOW after power loss although it was HIGH.
- Fixed incorrect online state naming for devices using variants.
- Fixed Valve and Nano 2 Relay devices being detected as an older hardware generation.
- BG-I49231: Fixed occasional presence triggers after a firmware update.
- SPD-I1: Fixed telemetry data flush without stop.
- Adapted the smoke algorithm.
- BG-I49737: Fixed Wallbox freezing after 49.7 days and no longer recognizing vehicles.
- BG-I49685: Valve Actuator names added during device search are now also applied to the valve output.
- BG-I49804: Fixed Tree Learning not providing interaction for digital pulse packets.
- BG-I50136: Fixed DALI configuration not being transmitted completely to the DALI Extension.
- Geiger Solidline driving parameters adapted according to Geiger requirements.
- Removed the update for Nano Motor Controller Air/Tree introduced in version 17.1.5.21.
- Removed the Nano DI Tree update since it caused problems.
Planning
- BG-I47914: Wireless Speaker is now available in global preselection in project planning.
- BG-I47497: Added missing products in project planning.
- BG-I47297: Added missing Dimmable Output 24VDC in global preselection.
- BG-I47916: New Touch Pure and Touch Pure Flex devices can now be edited with comboboxes.
AutoConfig
- BG-I47918: Lighting Controller no longer shows duplicated entries after a rerun.
- BG-I47972: Comfort functions are no longer incorrectly preselected.
- BG-I48278: Central Heating page now has the correct name and category.
- BG-I47686: AutoConfig no longer inserts incorrect ToDo entries or adds incorrect night mode information.
Setup
- BG-I48077: Installation is now allowed when the install directory is accessed via a symlink.
- BG-I47902: Stale ProgramData content is now deleted when upgrading an existing installation.
- Uninstaller unins000.exe is now code-signed.
Gateway Client
- Client states are no longer invalid when the client runs an outdated version.
- Gateway now transfers update files to Gen. 1 clients in streaming mode to avoid transfer issues.
- BG-I47915: Expert Mode now opens on Miniserver Gen. 1 clients without a timeout.
- BG-I48589: Miniserver task no longer starts without a configured gateway MAC address.
- BG-I48589: Protected commands are now rejected until the gateway MAC address is assigned.
- Deprecated non-concentrator clients. Use Multiplicator instead.
- BG-I49555: Device Monitor now applies user permissions to Client Miniserver devices.
Stability
- Fixed a Miniserver crash when generating the structure file with Audio Players in use.
- BG-I47427 / BG-I47602: Fixed a crash in the async undo thread caused by concurrent document access.
- BG-I47703: Fixed a Miniserver crash when sending intercom push notifications with modified users/groups.
- BG-I48017: Fixed a Miniserver watchdog caused by a race condition.
- BG-I48021: Fixed a Miniserver crash when closing TCP sockets.
- Fixed the Property Window rendering stale content when opening Qt dialogs.
- BG-I47474: Fixed a Config freeze after uploading a custom certificate.
- BG-I48153: Fixed saving Virtual Out HTTP response files on Miniserver Gen. 1.
- Fixed a possible Miniserver crash when receiving Tree packets.
- Fixed a Config crash when opening the User Management dialog.
- BG-I47439 / BG-I47447 / BG-I47484 / BG-I47509 / BG-I47519 / BG-I47558 / BG-I47534: Fixed multiple crashes.
- Fixed a crash on application close caused by the QNetworkAccessManager thread.
- BG-I47156: Fixed a Miniserver crash triggered by a malformed encrypted command.
- Fixed a Config crash when receiving new Partner Message Center entries.
- BG-I48490: Fixed a Miniserver crash when data is received from a plugin.
- BG-I48222: Fixed a crash on mouse release when Live View or Miniserver reconnect destroys the clicked control object.
- BG-I48838: Fixed a Miniserver Gen. 1 reboot when using Valve Tree devices.
- BG-I48223: Improved SSL send behavior when the receiver is busy.
- BG-I47512: Fixed occasional crashes triggered by Windows accessibility tools.
- BG-I47640: Fixed a Config crash when entering Live View.
- BG-I47463: Fixed an occasional Config crash when the project messages list is updated.
- BG-I49223: Fixed a Miniserver Gen. 2 watchdog reboot when the DNS or NTP server was incorrectly configured or unreachable.
- BG-I48015: Fixed a Gateway Miniserver Gen. 2 watchdog reboot while saving and sending the program to clients.
- BG-I49547: Fixed a Miniserver watchdog reboot during monthly statistics checks with large numbers of statistics files.
- BG-I49939: Fixed a crash when assigning an icon to a room group.
- BG-I49954: Fixed crashes when interacting with room groups.
- BG-I50370: Fixed Config freezing or crashing on startup without an internet connection.
- BG-I47855: Fixed a crash when selecting a room or category while the project tree was being rebuilt.
- BG-I48948: Fixed a crash shortly after connecting to a Miniserver.
- LOXONE Config now closes correctly when a dock panel is floating.
Usability
- BG-I47390: Fixed checkbox display in the Windows 11 update dialog.
- BG-I48200: Native language names now display correctly in the language switcher.
- BG-I47625: Fixed disappearing checkboxes in the SD card dialog.
- BG-I46328: Fixed Miniserver configuration window position inconsistency.
- BG-I46961: Reduced Sequence Controller indentation.
- BG-I41904: Background scrolling is now prevented while dialogs are open.
- BG-I46931: Multi-edit dialogs no longer reopen after close.
- Restored main window geometry before show.
- Fixed incorrect tooltip text in the User Management dialog.
- BG-I48570: Fixed an incorrect error message when a user had insufficient rights via Config.
- BG-I46828: Floating Property Window now selects the target block so it remains identifiable.
- Statistics CSV export now shows an error dialog when the target file cannot be written.
- R1701-T77: Memory Flag delay setting is hidden when using the default value.
- R1701-T79: Connected references are repositioned when showing or hiding function block inputs/outputs.
- R1701-T84: System message descriptions now clearly label room, installation place, and device type.
- BG-I48539: Fixed the SD Card Maintenance dialog freezing after deleting files.
- BG-I45559: Property Window now updates while the SD card is being formatted.
- Fixed an incorrect window title in the Changelog dialog.
- Backspace now removes selected items, matching Delete key behavior.
- BG-I48717: AC API output now accepts an additional connector when Touch Pure Flex is already connected.
- BG-I48916: Device Status dialog now shows the room for DALI devices.
- BG-I49262: Added missing translations in System Status messages for cabinet and installation location.
- BG-I48871: Load Manager configuration dialog no longer resizes unexpectedly when changing load priorities.
- BG-I49078: Command Recognition preview now updates the detected value while editing and keeps cursor position stable.
- Pressing Enter in the My Miniservers and Connect to Miniserver dialogs now triggers Connect.
- BG-I49755: Fixed the initial size of the Energy Flow Monitor configuration dialog.
- BG-I50241: My Miniservers dialog now updates address fields after selecting a different Miniserver.
- BG-I41830: Grouped inherited permission paths in the Browse Permissions dialog.
- Floating tree and property panels are no longer lost after restarting Config.
- Unpinned dock panels no longer close when clicking into their search field.
- Property panel no longer stops updating while a tree or panel is floating.
Exosphere
- Fixed repeated workspace requests caused by an infinite retry loop after 401 Unauthorized.
- R1701-T9: Statistics of controls on a Client Miniserver are now returned correctly.
- BG-I48668: Fixed Exosphere login in Config.
- Exosphere 1.3.3:
- Double values above 1.0000000000000000e+256 are now ignored.
- Double values are now rounded to three decimal places.
- Plugin obsolete message now disappears after the plugin is active again.
- BG-I47856: Gateway now returns historical statistics from client Miniservers correctly.
Modbus
- BG-I48320: Modbus TCP now allows up to 300 actors instead of using the RTU limit of 254.
Remote Connect
- Push notifications are now sent without delay.
Trust
- BG-I49451: Improved user data synchronization when edited in quick succession, especially for NFC codes.
Security
- BG-I49640: AAL Smart Alarm no longer loses selected buzzer alarm outputs after saving.
Multiplicator
- BG-I49177: Transferred page and device selections are no longer reset when adding a new Miniserver.
- BG-I49766: Touch Pure Flex “Show Input” settings can now be edited per managed Miniserver.
- BG-I49380: Changing a block’s icon now marks the block as a Multiplicator deviation.
- BG-I49381: Changing an IRC schedule now marks only the IRC block as a deviation instead of its connected inputs/outputs and the rest of the page.
SD Card
- BG-I49673: SD Card Manager no longer shows information from the previously selected entry.
Plugins
- Honeywell Plugin 1.0.3:
- Fixed a disconnect deadlock when the logout command could not be sent due to a websocket problem.
- OCPP Plugin 1.4.7:
- Fixed a crash during initialization.
- Updated translations.
LOXONE Config 17.1 Release Candidate
New
MCP Server for Miniserver
- Added MCP Server plugin support.
- Allows integration of the Miniserver into AI tools.
- Available via Network Periphery.
- Added support for assistants to retrieve hourly outdoor weather forecasts in addition to current conditions.
FIAS PMS Integration
- Added user management support for check-in and check-out events.
- Added room information inputs for automation use cases.
- Added NFC-based access management.
BMW CarData
- Added BMW vehicle data integration for the Miniserver.
- Added one-time authorization via BMW account using the device code flow.
- Added vehicle signals for state of charge, electric range, mileage, door lock status, charging state, distance from home, and additional values.
- Added a manual polling trigger to fetch vehicle data on demand.
- Added support for up to 20 vehicles per Miniserver.
Segway Navimow Integration
- Added integration for Segway Navimow robotic lawn mowers.
- Requires Miniserver Gen. 2 with firmware 17.1 or newer.
- Supports up to 10 Navimow devices per Miniserver.
Room Grouping
- Added support for nested room groups with configurable icons and ratings.
- Added navigable group cards in the Rooms tab of the App.
- Added support for room favourites within groups based on room rating.
- Added group sorting by rating.
LOXONE radio
- Real music: 13 streams, updated daily — includes hits and evergreens across genres.
- Free and ad-free: no ad breaks and no licensing fees* — just music, uninterrupted.
- Legal and hassle-free: no need to worry about music licenses, even in commercial settings.*
- Ready to stream: via the LOXONE App, triggered by presence, time schedule, or manually.
General
- Added support for the Smoke & Presence Detector Air/Tree.
- A3D9-T2290: Simplified “Installation Location” handling.
- Removed for devices that act at their installation point.
- Kept for devices controlling elements in other locations.
- Existing projects remain unchanged.
- A3D9-T2171: Sauna Controller now supports DisplayEcho.
- BG-I47171: Automatic Designer now supports conditions for the Spot Price Optimizer.
- Reworked the Getting Started wizard UI.
- Implemented the new DockWidget system for the Property Window, Monitors, and Trees.
- R1701-T132: Improved SD card formatting performance by writing files directly to the SD card.
- R1701-T202: Added a new endpoint for service reachability health checks.
- FS1-T170: Added the RSSI RDC value in Air Diagnostics and Air Mesh.
- FS1-T141: Added automatic Airbase-RDC channel configuration when adding RDC devices.
- BG-I49917: Updated the description of the default alarm in the Alarm Clock.
Access
- Intercom: Added the “Doorbell Ring Preview” setting.
- Controls whether the app shows a still image or live video when the doorbell rings.
- Still image is the default.
- The still image captures the moment the doorbell was pressed.
- Requires app support.
Diagnostics
- Added an option to save Health Check and Device Diagnostics results as a PDF report.
- BG-I48823: Health Check result messages are now colored based on severity.
Lighting
- Added LC5–LC8 light circuit inputs to the Lighting Controller.
- Autoprogramming: created Light Controller moods now get a matching icon.
Audio
- R1701-T111: Added a CPU temperature diagnosis input for the Audioserver and connected audio devices.
Planning
- Added new Leaf Tree/Air articles.
- Added automatic calculation for Leaf ventilation.
- R1701-T78: Added the room type “Outdoor Area”.
Energy
- BG-I47277: Added the Peak Load Manager.
- Added the output “Available Power Peak” (ApPeak).
- Starts with MaxTp at the beginning of the interval.
- Gradually decreases to meet the power budget MaxP.
- Load Shedding now uses ApPeak for calculations.
- Input Gpwr can now add PV export power to the Ap and ApPeak outputs when negative.
Energy Flow Monitor
- Added current total consumer power output.
Climate
- BG-T4902: Intelligent Room Controller now automatically adapts the comfort range for heating-only or cooling-only capabilities.
Usability
- R1701-T1: Added automatic naming for selected function blocks using the room name.
- Applied on creation.
- Applied when the room name changes.
- Applied when the room assignment changes.
- Converted old programs accordingly.
- Device Status now shows the device IP/address in a new Info column.
- Migrated the Alarm Clock dialog to the modern Qt interface.
- Migrated the Room and Category dialog to the modern Qt interface.
- Migrated the State Text dialog to the modern Qt interface.
- Added support for deleting empty rows.
- Improved column sizing and tooltips.
- Improved the Miniserver connection workflow and credential handling.
- Added support for selecting local or external connection modes.
- Added project context to keychain entries.
- Preserved passwords when switching users.
- Decoupled project keychain usage from project management and connection handling.
- Added My Miniservers for Miniserver-specific credentials.
- Added My Credentials for reusable credentials independent of a Miniserver.
- Added access to My Credentials from the Connect dialog.
- Added support for credentials that are not tied to a specific Miniserver serial number.
- Credential selection now only fills username and password and leaves Miniserver addresses unchanged.
Devices
- Added Device Telemetry.
- Sends device diagnostics information to LOXONE.
- Can be activated with the “Enable Device Logging” document setting.
- A remote server defines which device types or serial numbers are monitored.
- Monitored devices send cyclical diagnostic information to the Miniserver.
- The Miniserver forwards the data to a cloud server.
- Communication is encrypted and does not contain sensitive data.
- Added Wallbox Air/Tree binaries.
- Added Touch Pure Flex Gold variants.
- Added AC Control Tree, Hörmann Tree, and Modbus Tree.
- Updated Air Master binaries.
- C7WT-T414: Added Air Base adaptation for Large Update.
- Added a new RDC wake-up channel and RDC wake-up improvements.
- Added Touch Controller support for Touch Pure for Nano.
- Added support for the Touch Controller IQS7222C.
- Added support for Nano IO and Nano Dimmer.
- FS1-T175: Device Status now shows an unknown battery state.
- Door Lock Air 17.01.06.03:
- Added support for battery-operated Door Lock Air devices.
- Improved Air wakeup functionality.
- NFC Code Touch Air 17.01.06.22:
- Implemented Air wakeup signal routing.
- Ceiling Light Air 17.01.06.23:
- Implemented Air wakeup signal routing.
AC Control Tree
- Added a communication watchdog that triggers a reset after communication loss.
- Added logging of the last communication between AC Control and the AC unit before reboot.
- Added status messages when communication between AC Control and the AC unit is not possible.
- Added status messages showing the current AC error code for supported manufacturers.
Plugins
- Fronius Plugin 1.4.27:
- Added verification of AC output power limits.
- Added a notification if control is non-functional.
- Updated documentation.
- Improved error handling and system stability.
- Plugin Framework:
- Added support for SVG icons in the ribbon and device status panel.
Stability
- Reworked the Miniserver Health Check to provide additional diagnostic information.
Fixed
General
- BG-I43835: Automatic rules now reactivate correctly after a restart or update.
- BG-I48228: Property window now shows “Device Type” when an IO of a device is selected.
- BG-I48284: Central Audio OFF input negation now blocks only inputs and not AP.
- BG-I46736: Miniserver Client is no longer incorrectly reported as offline.
- BG-I44570: DispPc from a switch no longer blocks the OFF input.
- BG-I48149: Central inputs now work correctly when the user interface password is enabled.
- BG-I48161: Fire & Water Alarm now triggers correctly for negative maximum temperature values.
- BG-I47783: Text Generator <time.date> no longer shows an incorrect date after 22:00.
- BG-I43675: Wallbox Air NFC Code Touch Tree update now completes correctly.
- BG-I47517: Intelligent Room Controller history now differentiates heating and cooling preparation phases.
- BG-I47516: Adapted the severity description for custom system messages.
- BG-I47333: Intelligent Room Controller statistics now show the correct unit in the app.
- Energy Flow Monitor meters are now shown correctly in regular visualization.
- BG-I47968 / BG-I47998: Removed the error code from the Client/Gateway error message.
- BG-I47999: Fixed a blank error message when entering Client/Gateway mode with different credentials.
- Fixed a race condition while waiting for the logon response from the Miniserver.
- Fixed HTTP requests from Config to the Miniserver not using Basic Auth headers.
- BG-I47321: Fixed Miniserver replacement with factory credentials and HTTPS redirect enabled.
- BG-I47249: Miniserver no longer queries register.loxonecloud when Remote Connect is disabled.
- BG-I47677: Tabs are now escaped in device status messages.
- BG-I46915: Fixed the language mismatch warning reappearing after saving to the Miniserver in the same session.
- BG-I47939: Fixed an incorrect message box dialog size in some cases.
- BG-I47971: Fixed action enablement for unregistering all push devices.
- BG-I47907: Object configuration dialog can no longer be resized below its minimum size.
- BG-I47877: Property window read-only text editor no longer overlaps property labels.
- BG-I47865: Fixed the selection update when editing an object by double-click.
- BG-I47862: Fixed a Property Window repaint issue after the Help View was opened.
- BG-I47791: Removed the “Insert Extension” action from the “Tree Turbo” ribbon context panel.
- BG-I48047: Exosphere projects are now appended instead of prepended to the project list.
- BG-I47940: Quick Access panel no longer hides actions after opening a project.
- BG-I48138: Managed Tablet setup code dialog is now positioned correctly.
- BG-I47693: User group “Nobody” is no longer visible in the multi-edit dialog when editing all user groups.
- Fixed an incorrect character in the SKY language menu.
- BG-I47375: Improved authentication error def.log entries.
- BG-I47897: Fixed CLxStringU comparison operators performing pointer comparison instead of string comparison.
- BG-I46609: Fixed interfering tooltips in the Property Window.
- BG-I47420: Fixed combobox rendering in table/tree views on Windows 11.
- BG-I46953: Update notification panel now shows buttons correctly.
- BG-I47465: Fixed an incorrect time editor value when the AM/PM format was used.
- BG-I47440: Entire row is now selectable in Tree Views.
- BG-I43804: Added a button to abort an ongoing Miniserver connection attempt.
- BG-I47492: Fixed a possible crash when switching the actor type of a DALI device.
- BG-I47753: Fixed an SD format dialog failure when “overwrite data” was selected.
- BG-I47429: Fixed the HVAC Controller Y2 output description for “Heat Pump with Electric Backup”.
- BG-I47143: App WSP no longer appears in Tree Turbo search.
- BG-I47343: Teaching in a battery-powered Presence Sensor Air no longer shows inputs from a 24V device.
- BG-I47443: Repeating Auto Config no longer removes backup mode.
- BG-I47538: Gate with opening/closing duration set to zero no longer fails to stop.
- BG-I46911: Fixed chunked HTTPS response handling for Virtual HTTP Input.
- R20-I20: Valve Actuator Tree status LEDs can now be disabled.
- BG-I46277: Added a new custom message box implementation to fix layout issues.
- BG-I47398: Fixed Unicode conversion for Rooms/Categories in the ribbon.
- BG-I46760: Lighting Controller now shows “Not fully configured” when no settings are configured.
- BG-I46584: Stereo Output 1 is no longer always named as Audioserver when connected to the AP block.
- BG-I46419: Text Generator now shows the correct time in Live View.
- BG-I46895: Spot Price Optimizer now shows CHF instead of EUR for CH markets.
- BG-I46921: Audio Player function block now displays assigned devices correctly.
- BG-I44547: Fixed negated outputs and switches in Live View for affected outputs.
- BG-I46957: Auto Config no longer replaces a custom light mood.
- BG-I47041: Planning Tool now includes missing Signal White devices.
- BG-I46223: Fixed LED blink position calculation with installation and Tree branch sorting.
- BG-I47539: IRC fan speed presence setting now has a name in expert mode.
- Updated outdated icons and colors.
- BG-I47438: Velvet White Touch Pure Flex now shows correct inputs after updating from the Configurator.
- Users with update rights can no longer change the update level.
- BG-I47216: Monitoring online status can now be disabled for Modbus TCP devices.
- BG-I47417: Fixed incorrect reference names for TPF on Intercom.
- BG-I48288: Fixed Air Diagnostics behavior.
- BG-I48306: Fixed unknown devices shown in Air Diagnostics.
- BG-I47507: Existing network devices are now shown in the search dialog when the hostname uses a local TLD.
- BG-I48437: Download Exosphere project dialog now closes automatically in all cases.
- BG-I47853: Save template ribbon action is no longer displayed for unsupported selected devices/objects.
- BG-I47832: Audioserver is no longer created as a Wireless Speaker when generating a part list.
- BG-I48067: Fixed German grammar in audio device configuration.
- BG-I48695: Managed Tablet drag and drop now works.
- BG-I48818: Irrigation block now saves time settings correctly on first change.
- BG-I48950: Fixed KNX Extension group address count above 500.
- BG-I48085: IRCs now display values for valve actuators on outputs connected to FCFC or FCC.
- BG-I48800: Nano 2 Relay Tree no longer shows current flow when set to shading type.
- BG-I48741: GETINPUT now returns connected IRC2 humidity and CO2 input values.
- BG-I47101: Sequence Controller no longer shows an incorrect popup about changes.
- BG-I48934: Automatic Designer/Scenes no longer shows charge mode actions for a managed wallbox.
- BG-I42982: Presence parameter TWarn is now validated against Pet.
- BG-I45729: Presence acoustic reactivation is prevented while control is locked.
- BG-I48528: App Control URL setting now includes a description for universal links.
- BG-I49283: File upload timeout increased to 2 minutes for Miniserver Gen. 1 upload failures.
- BG-I48460: Backup files in the Project Backups dialog are now sorted correctly by date.
- BG-I47928: AutoConfig now switches to the Periphery tree when showing unassigned peripherals.
- BG-I47131: System status date now uses the system language.
- BG-I48949: Periphery tree online indicator now shows an “Online” tooltip.
- BG-I48238: Editing the name in the Property Window now sets the document modified flag correctly.
- BG-I48065: Project Backup dialog now shows the creation date correctly.
- BG-I48771: Opening the Miniserver update dialog no longer switches the selected ribbon category.
- BG-I48622: Editing after copy and paste now targets the correct function block.
- BG-I48596: Fixed an incorrect column layout in the New Miniserver page table.
- BG-I48516: Connecting from the New Miniserver page table now prefills the IP address.
- BG-I48829: Added the missing AC Control monitor action to the context ribbon.
- BG-I48066: Fixed incorrect or truncated project backup folder names when project names contain dots.
- BG-I48791: Fixed missing dialog buttons in some cases.
- BG-I47858: Corrected tooltip behavior in the Property Window.
- BG-I47609: Message boxes are no longer automatically closed by the Exosphere loading dialog.
- BG-I48984: Fixed an incorrect ribbon context panel for the Touch caption under Nano Dimmer Air devices.
- BG-I48155: LiCo buzzer history no longer creates two entries for short pulses.
- BG-I48348: AC Unit Controller forward thetaC is no longer visible when AC Control is not used.
- BG-I48366: API connector reference can now be deleted from the Fan Coil Unit Controller.
- BG-I48365: Deleted API connector references are no longer shown as connected.
- BG-I48148: Formula module no longer incorrectly shows “invalid formula” after updating to version 17.
- BG-I47861: Updated nomenclature for Automatic Shading outputs in Automatic Designer.
- BG-I48048: Update dialog no longer offers to load the project from the Miniserver when the local project is newer.
- BG-I48100: Statistics CSV export now includes units in the column headers.
- BG-I48107: Schedules from presets now appear in other projects.
- BG-I48254: Fixed the IRC block default fan speed when a Fan Coil Unit Controller is connected.
- BG-I48469: MinMax V1 now compares with V2 when not connected.
- BG-I48649: SPD Temperature Send Cycle setting now accepts zero as “Off”.
- BG-I48563: Text Generator output now updates time.time.
- Fixed a crash when saving to the Miniserver with child network devices.
- BG-I47510: Managed Tablet no longer changes brightness after an update.
- BG-I47383: Modbus TCP receive timeout system message is now set to historic when sensors are removed from the program.
- Fixed download of new plugin versions not working. Regression in 17.1.5.28.
- BG-I34091: Fixed a DALI device learned as the 64th device on a fully populated extension taking broadcast address 255.
- BG-I47938: User Management API NFC tags and access codes are no longer editable for trusted users.
- BG-I48156: Fixed status block icon colors from older projects not being converted to the current green.
- BG-I49384: Sequence Controller now supports == as the equality operator while keeping = compatible.
- Fixed a Modbus Sensors warning when a property value was adapted because the maximum number of fast sensors was reached.
- BG-I47997: Fixed Extension Search in the app not showing Dimmer and 1-Wire Extensions.
- Fixed empty schedules after RTD.
- BG-I49371: Sequence Controller now uses outputs S and TQ when adding custom loggers or trackers.
- BG-I47851: Touch Pure Flex API display text no longer switches off after changing a favorite.
- BG-I49429: Managed Tablet green banner can now be turned off in the app.
- BG-I48167: Quick Search window no longer stays open for affected dialog actions.
- BG-I47130: Firmware packages dialog no longer shows an empty entry in the configuration dialog.
- BG-I49048: Editing a name in the Property Window now immediately updates the control in the view.
- BG-I49166: Fixed Ribbon action visibility states not updating in some cases.
- BG-I49142: Function block IO description tooltip width is now limited.
- BG-I48866: Imported Belimo templates now appear in the popup menu list in all cases.
- BG-I49090: Restored Memory Flag delay parameter visibility and independent operation.
- BG-I49469: Central dialog now uses the correct “Display Name” column title.
- BG-I49772: Fixed a configuration lock-up when renaming a room.
- Fixed optional string settings with regex validation not being clearable.
- Fixed the Category Caption name being lost when closing the Room/Category dialog.
- Disabled updates for invalid Nano 2 Relay and Valve Actuator Tree versions.
- Fixed drag-and-drop handling where API actors and additional actors could be added to the wrong page.
- Fixed a potential telemetry-related memory leak.
- BG-I48467: Fixed incorrect negative values for signed 64-bit Modbus TCP sensors.
- BG-I48281: Fixed Fan Coil Unit Controller updates to the IRC OFF input.
- BG-I47911: Fixed inserting a Text Input into another Miniserver page for Network Intercom.
- BG-I48321: Fixed AC Controller receiving target temperature from IRC after being unlocked.
- BG-I48983: Alarm-triggered shading movements now include the alarm source in History.
- Quick Search popup is now displayed above dock widgets.
- Fixed missing save indication after inserting plugins requiring device learning.
- Fixed Config becoming unresponsive when opening the Room/Category dialog.
- BG-I49492: Statistics using “Every change (expert)” no longer create duplicate entries.
- BG-I49893: Fixed editing of Automatic Shading Rd parameter values via Property Window buttons.
- BG-I49616: Health Check dialog is now minimizable.
- BG-I49556: Added the missing editor for the Runtime Counter Maintenance parameter.
- BG-I49315: Clicking an empty page now resets the selected ribbon panel.
- BG-I49178: Backspace key now supports deletion in all locations where Delete was already supported.
- BG-I49773: Fixed mixed-up actions in the Quick Access panel.
- BG-I49892: HOME tab is now selected correctly when starting the Getting Started Wizard.
- BG-I49883: Room/Category dialog no longer appears unresponsive when deleting entries.
- BG-I49884: Newly created categories are now automatically selected when created from the Property Window.
- BG-I49918: Fixed missing prefilled user interface names in the Room/Category dialog on startup.
- BG-I49761: Custom colors selected in color dialogs now persist across Config sessions.
- BG-I50020: Fixed inconsistent button arrangement in system messages.
- BG-I50021: Added missing maximum device count text in Tree Turbo captions within the Periphery tree.
- BG-I49983: Fixed API connector drag-and-drop behavior when switching pages during insertion.
- BG-I48985: Statistics configured as “Each change (max. 1 per minute)” now flush suppressed values at the next minute boundary.
- BG-I50080: Fixed missing translations for system variables.
- BG-I50269: Added a delay to DNS health checks to prevent failures during the first run.
- BG-I50361: Added a minimum size for scrollbar handles in large views.
- BG-I49967: Fixed cut-off button text in the Miniserver state panel for some languages.
- BG-I49754: Fixed missing log entries in Device Diagnostics for certain devices and cases.
- BG-I47788: Fixed an issue where only one undo step was available in larger projects.
- Fixed ribbon action and button texts not updating correctly for rooms and categories in all cases.
- BG-I49623: Ribbon popup panels now close correctly after clicking or triggering an action.
- BG-I50237: Fixed automatic branch renaming after switching back from Tree Intercommunication to Link.
- BG-I48320: Fixed an incorrect “max count reached” message when inserting a Modbus template on a Modbus TCP server.
- BG-I49366: Multi-selection setting editors now update tree views after setting writes in all cases.
- BG-I49501: Fixed a missing linked object indicator on function blocks after copy and paste.
- BG-I49403: Burglar Alarm history now shows whether Window Handle Air was triggered by vibration or opening.
- BG-I49302: AC Central Controller mode changes are now displayed in Config.
- BG-I49041: Fixed Stereo Extension system temperature placement when the channel was already placed.
- BG-I48943: Fixed Thermal Solar Controller pump stopping too early.
- BG-I48790: Fixed incorrect Hz calculation for the Pulse Counter F input.
- BG-I49849: Fixed painting issues in the shared multiplicator settings dialog after editing.
- BG-I49955: Fixed very large projects failing to download or open from Exosphere.
- BG-147707: Fixed Ping block unlocking when not connected to Config.
- BG-I46655: Fixed the warning message device count for the Wallbox Air Tree Extension.
- BG-I49721: Replaced Tree Extensions are now searchable in Live Learning.
- BG-I49586: Added a LOXONE Config warning for Gen. 1 Miniservers before an update when memory is low.
- BG-I50067: Current time now updates while simulation is active.
- BG-I49072: Fixed time handling in AM/PM format in Simulation and the Property Window.
- BG-I50086: Trust periphery tree now uses the corresponding Miniserver type icon.
- BG-I50048: Floating Property Window now considers multi-selection in all cases when opened.
- BG-I50142: Command Recognition dialog now auto-scrolls to the found result.
- BG-I49379: Fixed the wrong configuration dialog opening when an intercom caption was selected.
- BG-I50049: Fixed Air Diagnostics view positioning on diagnosis startup.
- BG-I50139: Fixed color picker dialog positioning when opened from table views.
- BG-I50143: Floating Property Window now activates correctly after opening.
- BG-I49851: Block names no longer change when cancelling creation of a new room while editing multiple blocks.
- Fixed a Config crash when right-clicking a room group.
- BG-I49930: Virtual Input UDP default value handling now allows values outside the min/max range when validation is disabled.
- Fixed an invalid Tesla plugin signature that caused a redownload on every restart and increased Config startup time.
- Category is no longer a fixed column in the multi-edit dialog.
Diagnostics
- BG-I49871: Health Check device runtime is no longer reset incorrectly for EnOcean, Relay, and RS485 Extension hardware version 2 when clicking “Reboot devices”.
- BG-I49871: Expanded the tooltip description for runtime estimation of older devices when hovering over device runtime.
Climate
- BG-I46532: Heating and Cooling Controller in a Gateway Client no longer switches to OFF when saving to the Miniserver in affected cases.
- BG-I47803: Fixed swapped theta LimC and theta LimH positions in the app.
- BG-I48082: Fixed incorrect Ha and Ca input values for FCC, FCFC, and FCCc.
- BG-I47766: IRC is no longer shown as actively heating when heating is unavailable.
- BG-I47513: IRC2/HCC no longer creates a continuous overheating request from a pulse on Eh.
- BG-I46613: Heating and Cooling Controller now transfers the heating/cooling block when Otm is set by logic.
- BG-I45992: IRC now starts the AC Controller correctly when using all configured sources.
- BG-I47724: AC Unit Controller now becomes active again after being locked via the OFF input.
- Intelligent Room Controller no longer shows an invalid fan speed on input or in the app when using multiple AC Unit Controllers.
- BG-I42067: Heating and Cooling Controller no longer enters an invalid operating mode when input changes while control is locked.
- BG-I48837: Fan Coil Central Controller now prepares separate thresholds for the app.
- AC Unit Controller can now be switched off in standalone mode.
- Fan Coil Central Controller now sets the capability bitmask.
- Intelligent Room Controller now sets cooling capabilities for Fan Coil Unit Controllers.
- BG-I48341: Intelligent Room Controller now adds the connection bit to the target temperature input.
- BG-I48293: Outdoor temperature no longer remains stuck on the Fan Coil Central Controller.
- BG-I47967: FCCc now shows correct information in the app when Otm = 0.
- BG-I47881: FCC, FCFC, and FCCc abbreviations are now differentiated.
- BG-I46496: Up/Down arrow in IRC Air control now reacts correctly.
- BG-I48477: Copied ACc no longer keeps the IRC connection when it should not be present.
- Intelligent Room Controller now forwards fan speed changes to the AC Unit Controller correctly.
- Fixed AC Unit Controller not turning off when fan speed is set to “Off”.
- BG-I49298: AC Central Controller now shows connected Room Controllers.
- BG-I49219: Changing fan speed via IRC or app now ends Silent Mode.
- BG-I48082: Fan Coil and Central Controllers now show states Ha and Hc correctly in Live View.
- BG-I44119: Fixed Leaf Tree not working after a Miniserver restart. The program must be saved to the Miniserver again after the update.
- BG-I49595: Bedroom automatic comfort timer end time now runs until 12:00 instead of 08:00.
- BG-I49598: Heating and Cooling Controller mode is no longer pre-selected when added to a project.
- A3D9-T1144: SOT is now ignored when at least one IRC is below frost protection temperature.
- BG-I46128: IRC no longer remains in Building Protection after disabling Away Mode.
- BG-I48208: AutoConfig no longer raises inactive CoolComfort temperature for heating-only rooms.
- BG-I49572: Fixed IRC presets containing additional settings.
- BG-I47866: Fan Coil Central Controller rooms are no longer shown in the app.
- BG-I48454: IRC no longer starts cooling preheating for fixed heating setpoints that were already reached.
- BG-I49719: AutoConfig now transfers the heating and cooling ban to IRC created with CCo.
- BG-I50141: OFF mode set by calendar is now sent to the app.
- BG-I49677: Deprecated heating and cooling period defaults are no longer created and undeletable.
- BG-I49791: IRC target temperature input is no longer ignored in fixed setpoint mode.
- BG-I49925: IRC no longer switches to comfort mode until midnight when Silent Mode is triggered from a connected AC Unit Controller.
- BG-I49462: AC Unit Controller default fan speed and airflow are now applied after switching on when fan speeds were removed.
- BG-I49497: AC Controller Tg API input now works after the IRC connection is removed.
- BG-I48833: AC and IRC fan control no longer stays off after saving to the Miniserver.
- BG-I50337: IRC no longer shows the Heatprotect system message when no cooling capabilities are present.
- BG-I50128: AC no longer turns on while the OFF input is active.
- BG-I49439: AC Control on a Room Controller now shows the open door/window pause reason without delay.
- BG-I49548: Extended overrides for AC and Fancoil to their Unit and Central Controller.
- BG-I49548: IRC now reports a heating/cooling forbidden override when an energy source prohibits the requested mode.
- BG-I49548: AC unit mode changes now refresh the room controller immediately.
- BG-I49548: Added an override when outdoor temperature is beyond the configured heating/cooling limit.
- BG-I49548: Added an override when the room requests a disabled heating or cooling mode on the AC unit.
- BG-I49548: Override entries now report the UUID of the causing block.
- BG-I49548: Locked AC unit is now reported separately from a switched-off unit.
- BG-I49548: Corrected reporting level and severity of door/window, lock, and mode-mismatch overrides.
- BG-I49679: IRC source replacement within one source-assignment session is now applied correctly.
- BG-I49715: IRC no longer disables an independently wired heating/cooling source on a generic valve output when AC Central Control changes seasonal mode.
- BG-I49894: IRC +/- buttons can no longer lower a fixed setpoint below frost protection or above heat protection.
- AC Unit Controller permanent-off lock no longer puts the connected IRC into a fixed setpoint until midnight.
Energy
- Energy Flow Monitor residual values are now shown for sub-meters.
- BG-I48272: Meter reading offset no longer leaks into day/week/month/year statistics.
- BG-I48053: Fixed Energy Manager calculation with minimum runtime during ramp-up.
- BG-I48275: Restored the Type column position in the Energy Flow Monitor dialog.
- BG-I48112: Fixed output names in the Energy Manager when more than two outputs were connected.
- BG-I48285: Meter statistics graph now carries the last recorded value forward instead of showing zero.
- BG-I49008: Spot Price Optimizer now calculates the cheapest hours for minimum runtime correctly.
- Fixed Energy Manager configuration dialog column sizing.
- Car Charger device address settings now hide the /dev/udp prefix and restore it automatically when required.
- BG-I50202: Statistics are now disabled after a block is removed from the Energy Flow Monitor.
- Fixed Energy Manager target power reduction when lower-priority loads were still blocked by minimum runtime.
- BG-I44736: Fixed different values and ratios in annual and total energies in the Energy Flow Monitor.
Lighting
- BG-I48166: Fixed DMX brightness drop in the CW/WW mixing range.
- BG-I49310: Improved Light Controller history description for blocked presence automatic due to an active mood.
- BG-I50071: Fixed LiCo remanence when using the LC input.
- BG-I48956: New DALI Extensions now default the lamp state update cycle to 600 seconds.
- BG-I49059: Fixed color mode retention when the brightness slider is set to zero.
- BG-I40453: Fixed Spot Fading Time being ignored for small fading differences.
- BG-I45144: Fixed Learning Dialog spot behavior causing “construction site light”.
Shading
- BG-I49900: Fixed Shading Period Calculated History shown after reboot.
Mailer
- BG-I50149: Added missing user notification after SMTP retries are exhausted.
Access
- BG-I50224: Fixed NFC learn webservice discovernfc failing immediately on the first attempt due to a stale learn result.
Audio
- New equalizer allows more precise control of single bands.
- BG-I48313: Extension LED no longer remains orange blinking.
- BG-I47761: Audio Player now sends volume configuration correctly in affected gateway constellations.
- BG-I47992: Fixed an incorrect “Project modified” notification when closing a dialog without changes.
- Fixed Master/Client Speaker audio dropouts.
- Fixed Wireless Speaker update progress reporting.
- Event volumes slightly increased to match playback volume.
- Fixed Wireless Speaker static IP configuration.
- Fixed Wireless Speaker DHCP hostname registration.
- Fixed Wireless Speaker Bluetooth fallback when WiFi is unavailable.
- Fixed race conditions and crashes related to Audioserver playback, AirPlay, and Bluetooth handling.
- BG-I48176: Source changes are now promoted correctly among stacked devices.
- BG-I49201: Fixed an incorrect blink state on the Audioserver.
- Bluetooth connection to muted player groups no longer starts all players in unsupported cases.
- Bluetooth connection to non-grouped players now works.
- BG-I49076: Wireless Speaker now shows system temperature.
- BG-I49237: Device Status commands are now sent to the correct device.
- Live Learning now supports replacing a Wireless Speaker.
- BG-I48765: Device Status now shows the correct icon for Miniserver Compact.
- BG-I46916: Tree Turbo devices learned via the app are now shown as online in the tree.
- BG-I47646: Audio Player now shows the correct history message when presence is active and playback is paused.
- Fixed Stereo Extensions in split mode not working after an EQ revert.
- Equalizer reverted to old implementation and loudness was removed.
- BG-I47431: Audioserver now reconnects immediately when the secure session is lost.
- Fixed a crash caused by a library.
- Fixed Spotify “Account not premium” error message for affected accounts.
- BG-T5148: Added a cover art minification option for Room Favourites.
- BG-I49797: Removed unnecessary event loading on WebSocket connection.
- BG-I49809: Fixed invalid Room Favourite IDs being set via API.
- BG-I49688: Fixed playback issues when adding multiple Wireless Speakers to one player.
- Fixed incorrect Audioserver LED states shown in Config.
- Fixed Spotify room favorites not starting in some grouped environments.
- Fixed Spotify volume transitions when switching between Spotify and TuneIn.
- BG-I50068: Fixed Spotify default account selection after migration to the new eSDK.
- BG-I50148: Fixed Spotify playback issue on presence and incorrect playlist selection.
- Fixed Room Favourite priority handling where the Player selected Room Favourite ID 1 instead of the first Room Favourite.
- Fixed RTD not disconnecting Spotify Connect sessions.
- BG-I49360: Fixed Music Extension appearing offline after an Audioserver update until the firmware update completed.
- BG-I49401: Fixed autogrouping issues when audio players were inside a group.
- Fixed an issue introduced in 17.1.6.18 that prevented proper updating.
- BG-I43390: Changing the Audioplayer preset in Config now triggers changes on the Audioplayer.
- BG-I49490: Fixed diagnostic inputs of a Stereo Extension not being insertable when its audio output was already used.
- Fixed Spotify Connect issues on Miniserver Compact and Stereo Extensions.
- Wireless Speaker now gathers network time correctly when not paired with a Miniserver.
- BG-I50235: Fixed USB stick folders not being recognized.
- BG-I49711: Audioserver Player no longer logs a “reset to default” history entry when a preset/template is updated.
- BG-I50366 / BG-I50075: Fixed unintentional start of players when grouped and Spotify is selected on a single player.
- Local Audioserver players are no longer shown offline until the next service restart or save to the Miniserver in rare cases.
- Fixed Audioservers not being updateable and added the missing update path with a proper message.
Devices
- Touch & Grill now shows the correct battery value outside the function block.
- BG-I47768: Fixed volume thresholds graph after reset.
- BG-I45340: Tree now shows devices available for pairing when already paired on another branch.
- BG-I45162: Valve Actuator Air/Tree Gen. 2 start position detection can now be disabled.
- BG-I46362 / BG-I46639: Valve Actuator Air/Tree Gen. 2 devices now open fully.
- BG-I47995: Live Learning no longer shows replaced devices again after restarting search.
- BG-I40274: Leha shading now works reliably.
- Updated Nano Motor Controller Air/Tree binaries to 17.01.05.11.
- Telemetry is no longer incorrectly reactivated.
- BG-I45000: Fixed NFC behavior when two different NFCs are connected to one Anfc.
- BG-I45020: Fixed an incorrect popup when inserting T2AB to a Wallbox Air.
- Touch Tree, Touch Pure Tree, and Touch Pure CO2 Tree now respond reliably to touches.
- BG-I46364: Touch Pure Air backlight actor is removed correctly when the device is battery-operated.
- Updated Power Supply and Backup binary to 17.01.04.28.
- BG-I25399: Fixed device reset during TechReport webservice polling.
- BG-I27829 / BG-I33447 / BG-I39476: Fixed false “Backup active” and “Fuses blown” in supply-only mode on mains loss.
- Updated Smoke Presence Detector Air/Tree EU binaries to 17.01.05.07.
- BG-I48845: Volume thresholds dialog on the Presence Sensor no longer triggers auto-connect that logs out other users.
- Touch Pure Flex input blocks placed on the program page now refresh their name after button reassignment and configuration import.
- Updated Presence Sensor Tree binaries.
- BG-I45109: Fixed Presence Sensor keeping presence after a power reset.
- BG-I43936: Fixed Presence Sensor not blinking out of the box.
- Updated Shading Actuator Air binaries.
- BG-I40593: Fixed end position setting “Both directions” staying active for only about one second.
- Updated Nano DI Tree binaries.
- BG-I44616: Fixed Nano DI Tree reliability after a power-on reset.
- Fixed the first input sometimes being shown as LOW after power loss although it was HIGH.
- Fixed incorrect online state naming for devices using variants.
- Fixed Valve and Nano 2 Relay devices being detected as an older hardware generation.
- BG-I49231: Fixed occasional presence triggers after a firmware update.
- SPD-I1: Fixed telemetry data flush without stop.
- Adapted the smoke algorithm.
- BG-I49737: Fixed Wallbox freezing after 49.7 days and no longer recognizing vehicles.
- BG-I49685: Valve Actuator names added during device search are now also applied to the valve output.
- BG-I49804: Fixed Tree Learning not providing interaction for digital pulse packets.
- BG-I50136: Fixed DALI configuration not being transmitted completely to the DALI Extension.
- Geiger Solidline driving parameters adapted according to Geiger requirements.
- Removed the update for Nano Motor Controller Air/Tree introduced in version 17.1.5.21.
Planning
- BG-I47914: Wireless Speaker is now available in global preselection in project planning.
- BG-I47497: Added missing products in project planning.
- BG-I47297: Added missing Dimmable Output 24VDC in global preselection.
- BG-I47916: New Touch Pure and Touch Pure Flex devices can now be edited with comboboxes.
AutoConfig
- BG-I47918: Lighting Controller no longer shows duplicated entries after a rerun.
- BG-I47972: Comfort functions are no longer incorrectly preselected.
- BG-I48278: Central Heating page now has the correct name and category.
- BG-I47686: AutoConfig no longer inserts incorrect ToDo entries or adds incorrect night mode information.
Setup
- BG-I48077: Installation is now allowed when the install directory is accessed via a symlink.
- BG-I47902: Stale ProgramData content is now deleted when upgrading an existing installation.
- Uninstaller unins000.exe is now code-signed.
Gateway Client
- Client states are no longer invalid when the client runs an outdated version.
- Gateway now transfers update files to Gen. 1 clients in streaming mode to avoid transfer issues.
- BG-I47915: Expert Mode now opens on Miniserver Gen. 1 clients without a timeout.
- BG-I48589: Miniserver task no longer starts without a configured gateway MAC address.
- BG-I48589: Protected commands are now rejected until the gateway MAC address is assigned.
- Deprecated non-concentrator clients. Use Multiplicator instead.
- BG-I49555: Device Monitor now applies user permissions to Client Miniserver devices.
Stability
- Fixed a Miniserver crash when generating the structure file with Audio Players in use.
- BG-I47427 / BG-I47602: Fixed a crash in the async undo thread caused by concurrent document access.
- BG-I47703: Fixed a Miniserver crash when sending intercom push notifications with modified users/groups.
- BG-I48017: Fixed a Miniserver watchdog caused by a race condition.
- BG-I48021: Fixed a Miniserver crash when closing TCP sockets.
- Fixed the Property Window rendering stale content when opening Qt dialogs.
- BG-I47474: Fixed a Config freeze after uploading a custom certificate.
- BG-I48153: Fixed saving Virtual Out HTTP response files on Miniserver Gen. 1.
- Fixed a possible Miniserver crash when receiving Tree packets.
- Fixed a Config crash when opening the User Management dialog.
- BG-I47439 / BG-I47447 / BG-I47484 / BG-I47509 / BG-I47519 / BG-I47558 / BG-I47534: Fixed multiple crashes.
- Fixed a crash on application close caused by the QNetworkAccessManager thread.
- BG-I47156: Fixed a Miniserver crash triggered by a malformed encrypted command.
- Fixed a Config crash when receiving new Partner Message Center entries.
- BG-I48490: Fixed a Miniserver crash when data is received from a plugin.
- BG-I48222: Fixed a crash on mouse release when Live View or Miniserver reconnect destroys the clicked control object.
- BG-I48838: Fixed a Miniserver Gen. 1 reboot when using Valve Tree devices.
- BG-I48223: Improved SSL send behavior when the receiver is busy.
- BG-I47512: Fixed occasional crashes triggered by Windows accessibility tools.
- BG-I47640: Fixed a Config crash when entering Live View.
- BG-I47463: Fixed an occasional Config crash when the project messages list is updated.
- BG-I49223: Fixed a Miniserver Gen. 2 watchdog reboot when the DNS or NTP server was incorrectly configured or unreachable.
- BG-I48015: Fixed a Gateway Miniserver Gen. 2 watchdog reboot while saving and sending the program to clients.
- BG-I49547: Fixed a Miniserver watchdog reboot during monthly statistics checks with large numbers of statistics files.
- BG-I49939: Fixed a crash when assigning an icon to a room group.
- BG-I49954: Fixed crashes when interacting with room groups.
- BG-I50370: Fixed Config freezing or crashing on startup without an internet connection.
- BG-I47855: Fixed a crash when selecting a room or category while the project tree was being rebuilt.
- BG-I48948: Fixed a crash shortly after connecting to a Miniserver.
- LOXONE Config now closes correctly when a dock panel is floating.
Usability
- BG-I47390: Fixed checkbox display in the Windows 11 update dialog.
- BG-I48200: Native language names now display correctly in the language switcher.
- BG-I47625: Fixed disappearing checkboxes in the SD card dialog.
- BG-I46328: Fixed Miniserver configuration window position inconsistency.
- BG-I46961: Reduced Sequence Controller indentation.
- BG-I41904: Background scrolling is now prevented while dialogs are open.
- BG-I46931: Multi-edit dialogs no longer reopen after close.
- Restored main window geometry before show.
- Fixed incorrect tooltip text in the User Management dialog.
- BG-I48570: Fixed an incorrect error message when a user had insufficient rights via Config.
- BG-I46828: Floating Property Window now selects the target block so it remains identifiable.
- Statistics CSV export now shows an error dialog when the target file cannot be written.
- R1701-T77: Memory Flag delay setting is hidden when using the default value.
- R1701-T79: Connected references are repositioned when showing or hiding function block inputs/outputs.
- R1701-T84: System message descriptions now clearly label room, installation place, and device type.
- BG-I48539: Fixed the SD Card Maintenance dialog freezing after deleting files.
- BG-I45559: Property Window now updates while the SD card is being formatted.
- Fixed an incorrect window title in the Changelog dialog.
- Backspace now removes selected items, matching Delete key behavior.
- BG-I48717: AC API output now accepts an additional connector when Touch Pure Flex is already connected.
- BG-I48916: Device Status dialog now shows the room for DALI devices.
- BG-I49262: Added missing translations in System Status messages for cabinet and installation location.
- BG-I48871: Load Manager configuration dialog no longer resizes unexpectedly when changing load priorities.
- BG-I49078: Command Recognition preview now updates the detected value while editing and keeps cursor position stable.
- Pressing Enter in the My Miniservers and Connect to Miniserver dialogs now triggers Connect.
- BG-I49755: Fixed the initial size of the Energy Flow Monitor configuration dialog.
- BG-I50241: My Miniservers dialog now updates address fields after selecting a different Miniserver.
- BG-I41830: Grouped inherited permission paths in the Browse Permissions dialog.
- Floating tree and property panels are no longer lost after restarting Config.
- Unpinned dock panels no longer close when clicking into their search field.
- Property panel no longer stops updating while a tree or panel is floating.
Exosphere
- Fixed repeated workspace requests caused by an infinite retry loop after 401 Unauthorized.
- R1701-T9: Statistics of controls on a Client Miniserver are now returned correctly.
- BG-I48668: Fixed Exosphere login in Config.
- Exosphere 1.3.3:
- Double values above 1.0000000000000000e+256 are now ignored.
- Double values are now rounded to three decimal places.
- Plugin obsolete message now disappears after the plugin is active again.
- BG-I47856: Gateway now returns historical statistics from client Miniservers correctly.
Modbus
- BG-I48320: Modbus TCP now allows up to 300 actors instead of using the RTU limit of 254.
Remote Connect
- Push notifications are now sent without delay.
Trust
- BG-I49451: Improved user data synchronization when edited in quick succession, especially for NFC codes.
Security
- BG-I49640: AAL Smart Alarm no longer loses selected buzzer alarm outputs after saving.
Multiplicator
- BG-I49177: Transferred page and device selections are no longer reset when adding a new Miniserver.
- BG-I49766: Touch Pure Flex “Show Input” settings can now be edited per managed Miniserver.
- BG-I49380: Changing a block’s icon now marks the block as a Multiplicator deviation.
- BG-I49381: Changing an IRC schedule now marks only the IRC block as a deviation instead of its connected inputs/outputs and the rest of the page.
SD Card
- BG-I49673: SD Card Manager no longer shows information from the previously selected entry.
Plugins
- Honeywell Plugin 1.0.3:
- Fixed a disconnect deadlock when the logout command could not be sent due to a websocket problem.
- OCPP Plugin 1.4.7:
- Fixed a crash during initialization.
- Updated translations.
LOXONE Config 17.1 Beta 6
New
General
- R1701-T202: Added new endpoint for service reachability health checks.
- FS1-T170: Added RssiRDC value in Air Diagnostics and Air Mesh inside Config.
- FS1-T141: Added automatic Airbase-RDC channel configuration when adding RDC devices.
- BG-I49917: Updated the default alarm description in the alarm clock.
Diagnostics
- BG-I48823: Added severity-based coloring for health check result messages.
Devices
- FS1-T175: Added support in Device Status to show unknown battery state.
- Door Lock Air 17.01.06.03:
- Added support for battery-operated Door Lock Air devices.
- Improved Air wakeup functionality.
- NFC Code Touch Air 17.01.06.22:
- Implemented Air wakeup signal routing.
- Ceiling Light Air 17.01.06.23:
- Implemented Air wakeup signal routing.
Plugin
- MCP Server 1.0.0:
- Added support for assistants to retrieve hourly outdoor weather forecasts in addition to current conditions.
Fixed
General
- BG-I50080: Fixed missing translations for system variables.
- BG-I50269: Added a delay to DNS health checks to prevent failures during the first run caused by tests executing too quickly.
- BG-I50361: Added a minimum size for scrollbar handles to improve usability in large views.
- BG-I49967: Fixed cut-off button text in the Miniserver state panel for some languages.
- BG-I49754: Fixed missing log entries in the device diagnostics view for certain devices and cases.
- BG-I47788: Fixed an issue where only one undo step was available in larger projects.
- Fixed ribbon action and button texts not updating correctly for rooms and categories in all cases.
- BG-I49623: Fixed ribbon popup panels not always closing after clicking or triggering an action.
- BG-I50237: Fixed automatic branch renaming not working after switching back from Tree Intercommunication to Link.
- BG-I48320: Fixed an incorrect “max count reached” message when inserting a Modbus template on a Modbus TCP server.
- BG-I49366: Fixed multi-selection setting editors not updating tree views after setting writes in all cases.
- BG-I49501: Fixed missing linked object indicator on function blocks after copy and paste.
- BG-I49403: Fixed Burglar Alarm history not showing whether Window Handle Air was triggered by vibration or opening.
- BG-I49302: Fixed AC Central Controller mode changes not being displayed in Config.
- BG-I49041: Fixed Stereo Extension system temperature placement when the channel was already placed.
- BG-I48943: Fixed Thermal Solar Controller pump stopping too early.
- BG-I48790: Fixed incorrect Hz calculation for Pulse Counter F input.
- BG-I49849: Fixed painting issues in the shared Multiplicator settings dialog after editing in some cases.
- BG-I49955: Fixed very large projects failing to download or open from Exosphere.
- BG-147707: Fixed Ping block unlocking when not connected to Config.
- BG-I46655: Fixed warning message showing the correct number of devices for Wallbox Air Tree Extension.
- BG-I49721: Fixed replaced Tree Extensions not being searchable in Live Learning.
- BG-I49586: Added LOXONE Config warning for Gen1 Miniservers before update when memory is low.
- BG-I48866: Fixed imported Belimo templates not appearing in the popup menu list in all cases.
- BG-I50067: Fixed current time not updating while simulation was active in all cases.
- BG-I49072: Fixed time not changing correctly in AM/PM format in Simulation and the property window.
- BG-I50086: Fixed Trust periphery tree to use the icon of the corresponding Miniserver type.
- BG-I50048: Fixed floating property window not considering multi-selection in all cases when opened.
- BG-I50142: Fixed Command Recognition dialog not auto-scrolling to the found result in the editor or view.
- BG-I49379: Fixed wrong configuration dialog opening when an intercom caption was selected.
- BG-I50049: Fixed Air Diagnostics view positioning on diagnosis startup to avoid required user scrolling.
- BG-I50139: Fixed color picker dialog positioning when opened from table views.
- BG-I50143: Fixed floating property window not being activated correctly after opening, causing input events to close it immediately.
- BG-I49851: Fixed block names changing when cancelling creation of a new room while editing multiple blocks.
- Fixed Config crash when right-clicking a room group.
- Fixed possible telemetry memory leak.
- BG-I49930: Fixed Virtual Input UDP default value handling so values outside the min/max range can be set when range validation is disabled.
- BG-I49871: Healthcheck:
- Fixed runtime of EnOcean, Relay, and RS485 Extension devices with hardware version 2 not being reset when clicking “Reboot devices”.
- Expanded the tooltip description for runtime estimation of older devices.
- Reverted HomeKit version to the certified version for release.
- Disabled device telemetry for release builds.
- Fixed invalid Tesla plugin signature, which caused a redownload on each restart and increased LOXONE Config startup time.
- Disabled persisting of auto-resolved IP addresses because the feature requires further work.
- Auto resolving remains available as already included in the last release.
- Updated MCP Server documentation and bumped the version to 1.0.0.
Stability
- BG-I50370: Fixed Config freezing or crashing on startup when no internet connection was available.
- BG-I47855: Fixed a crash when selecting a room or category while the project tree was being rebuilt.
- BG-I48948: Fixed a crash shortly after a connection to a Miniserver was established.
Devices
- BG-I49231: Fixed occasional presence triggers after a firmware update.
- SPD-I1: Fixed telemetry data flush without stop.
- Adapted the smoke algorithm.
- BG-I49737: Fixed Wallbox freezing after 49.7 days and no longer recognizing vehicles.
- BG-I49685: Fixed naming behavior for Valve Actuators added during device search so the name is also applied to the valve output.
- BG-I49804: Fixed Tree Learning not providing interaction for digital pulse packets.
- BG-I50136: Fixed DALI configuration not being transmitted completely to the DALI Extension.
- Geiger Solidline: Adapted driving parameters according to Geiger requirements.
Climate
- BG-I48208: Fixed AutoConfig raising inactive CoolComfort temperature for heating-only rooms.
- BG-I49572: Fixed IRC presets containing additional settings.
- BG-I47866: Fixed Fan Coil Central Controller rooms being shown in the app.
- BG-I48454: Fixed IRC starting cooling preheating for fixed heating setpoints that were already reached.
- BG-I49719: Fixed AutoConfig not transferring heating and cooling ban to IRC created with CCo.
- BG-I50141: Fixed Off mode set by calendar not being sent to the app.
- BG-I49677: Fixed deprecated heating and cooling period defaults being created and not deletable.
- BG-I49791: Fixed IRC target temperature input being ignored in fixed setpoint mode.
- BG-I49925: Fixed IRC switching to comfort mode until midnight when Silent mode was triggered from a connected AC Unit Controller.
- BG-I49462: Fixed AC Unit Controller default fan speed and airflow not being applied after switching on when fan speeds were removed.
- BG-I49497: Fixed AC Controller Tg API input no longer working after IRC connection was removed.
- BG-I48833: Fixed AC and IRC fan control staying off after saving to Miniserver.
- BG-I50337: Fixed Heat Protect system message being shown for Intelligent Room Controller when no cooling capabilities are present.
- BG-I50128: Fixed AC switching on even when input Off was active.
- BG-I49439: Fixed AC Control on a Room Controller not showing the open door/window pause reason immediately when the unit was off.
- BG-I49548: Extended AC and Fancoil overrides to their respective Unit and Central Controller.
- BG-I49548: Fixed Intelligent Room Controller silently idling when an energy source prohibited the requested heating or cooling mode by reporting the heating/cooling forbidden override.
- BG-I49548: Fixed AC unit mode changes not refreshing the room controller immediately, which could briefly show an incorrect unit-mode override after a heating/cooling switch.
- BG-I49548: Added an override for outdoor temperature beyond the configured heating/cooling limit.
- BG-I49548: Added an override for rooms requesting a heating or cooling mode that is disabled on the AC unit.
- BG-I49548: Fixed override entries to report the UUID of the block that caused them.
- BG-I49548: Fixed locked AC units, where Off input is held on, being reported the same as units that were simply switched off.
- BG-I49548: Corrected reporting level and severity of door/window, lock, and mode-mismatch overrides.
- BG-I49679: Fixed IRC source replacement in a single source-assignment session not being applied.
- BG-I49715: Fixed separate heating/cooling sources wired to a generic valve output being disabled when AC Central Control changed seasonal mode.
- BG-I49894: Fixed IRC +/- buttons allowing fixed setpoints below frost protection or above heat protection, which desynced the displayed temperature and disabled the buttons.
Lighting
- BG-I49059: Fixed color mode retention when the brightness slider was set to 0.
- BG-I50071: Fixed remanence on Lico not working with input LC.
- BG-I40453: Fixed Spot fading time being ignored for small fading differences.
- BG-I45144: Fixed Learning Dialog Spots behavior causing “construction site light”.
Shading
- BG-I49900: Fixed Shading Period Calculated History showing after reboot.
Mailer
- BG-I50149: Fixed missing user notification after SMTP retries were exhausted due to failed email delivery.
Access
- BG-I50224: Fixed NFC learn webservice discovernfc failing immediately with “NFC learn fail” on the first attempt due to stale learn result.
Audio
- Aligned LOXONE radio wording, station names, and covers with marketing requirements.
- BG-I50148: Fixed Spotify playback issue on presence and incorrect playlist selection.
- Fixed room favorite priority handling with Player selecting room favorite ID 1 instead of the first room favorite in the list.
- Fixed RTD not disconnecting Spotify Connect sessions, which allowed still-logged-in users to reuse the connection.
- BG-I49360: Fixed Music Extension appearing offline after Audioserver update until the device firmware update was completed.
- BG-I49401: Fixed autogrouping issues when audio players were themselves inside a group.
- Fixed an issue introduced in 17.1.6.18 that prevented proper updating.
- BG-I43390: Fixed changing Audioplayer preset in Config not triggering changes on the Audioplayer.
- BG-I49490: Fixed diagnostic inputs of a Stereo Extension not being insertable when its audio output was already used by an Audio Player.
- Fixed Spotify Connect not starting on Miniserver Compact and Stereo Extensions.
- Fixed players not being shown in the device picker and local Spotify accounts not playing on Miniserver Compact and Stereo Extensions.
- Fixed Wireless Speaker not always retrieving network time correctly when not paired with a Miniserver, which caused Spotify to fail.
- BG-I50235: Fixed USB stick folders not being recognized.
- BG-I49711: Fixed Audioserver Player logging a “reset to default” history entry when a control preset or template was updated.
Energy
- BG-I50202: Fixed statistics not being disabled after a block was removed from the Energy Flow Monitor.
- Fixed Energy Manager target power reduction when lower-priority loads were still blocked by minimum runtime.
- BG-I44736: Fixed different values and ratios in annual and total energies in the Energy Flow Monitor.
Usability
- BG-I50241: Fixed the My Miniservers dialog not updating address fields after selecting a different Miniserver.
- BG-I41830: Grouped inherited permission paths in the Browse Permissions dialog for controls with special parent-control handling.
Plugin
- FIAS PMS Integration 0.9.6:
- Removed Room Status input.
- Added keyservice retry when NFC learn fails.
- Updated documentation.
- McpServer
- Added support for assistants to confirm or clear system messages directly from the status overview.
- Standardized all tool timestamps to UTC in ISO 8601 format.
- Added Miniserver timezone reporting to the status overview.
- Fixed the plugin icon not showing in LOXONE Config.
- BG-I50159: OCPP Plugin 1.4.7:
- Fixed a crash during initialization.
- Updated translations.
LOXONE Config 17.1 Beta 5
New
General
- Implemented the new DockWidget system for Property Window, Monitors, and Trees (Periphery, Configuration, Rooms, Devices).
- R1701-T132: Improved SD card formatting performance by writing files directly to the SD card instead of creating a local image first.
Devices
- AC-Control Tree
- Added a communication watchdog that triggers a reset after communication loss is detected.
- Added logging of the last communication between AC-Control and the AC unit before reboot.
- Added status messages when communication between AC-Control and the AC unit is not possible.
- Added status messages showing the current AC error code for supported manufacturers (Daikin S21, Mitsubishi Heavy Industries, and Panasonic).
Plugins
- FIAS PMS Integration
- Added user management support for check-in and check-out events.
- Added room information inputs for automation use cases.
- Added NFC-based access management.
- MCP Server for Miniserver
- Added MCP Server plugin support.
- Allows integration of the Miniserver into AI tools.
- Available via Network Periphery.
- Plugin Framework
- Added support for SVG icons in the ribbon and device status panel.
Fixed
Stability
- BG-I49547: Fixed a Miniserver watchdog reboot during monthly statistics checks on installations with large numbers of statistics files.
- BG-I49939: Fixed a crash when assigning an icon to a room group.
- BG-I49954: Fixed a crash that could occur when the tree refreshed after deleting a room from a group.
- BG-I49954: Fixed crashes when interacting with room groups, including opening the context menu and pasting devices.
General
- Fixed a crash when opening the context menu of a room group.
- Fixed a potential telemetry-related memory leak.
- BG-I48467: Fixed incorrect negative values for signed 64-bit Modbus TCP sensors.
- BG-I48281: Fixed Fan Coil Unit Controller updates to the IRC Off input.
- BG-I47911: Fixed inserting a Text Input into another Miniserver page for Network Intercom.
- BG-I48321: Fixed AC Controller receiving target temperature from IRC after being unlocked.
- BG-I48983: Alarm-triggered shading movements now include the alarm source in History.
- Quick Search popup is now correctly displayed above dock widgets.
- Fixed missing save indication after inserting plugins requiring device learning.
- Fixed Config becoming unresponsive when opening the Room/Category dialog.
- BG-I49492: Statistics using “Every change (expert)” no longer create duplicate entries.
- BG-I49893: Fixed editing of Automatic Shading “Rd” parameter values via property window buttons.
- BG-I49616: Fixed the Health Check dialog not being minimizable.
- BG-I49556: Added the missing editor for the RuntimeCounter Maintenance parameter.
- BG-I49315: Clicking on an empty page now resets the selected ribbon panel.
- BG-I49178: Added Backspace key support for deletion in all locations where the Delete key was already supported.
- BG-I49773: Fixed mixed-up actions in the Quick Access panel.
- BG-I49892: Fixed the HOME tab not being selected correctly when starting the Getting Started Wizard.
- BG-I49883: Fixed the Room/Category dialog appearing unresponsive when deleting entries.
- BG-I49884: Newly created categories are now automatically selected when created from the property window.
- BG-I49918: Fixed missing prefilled user interface names in the Room/Category dialog on startup.
- BG-I49761: Custom colors selected in color dialogs are now persisted across Config sessions.
- BG-I50020: Fixed inconsistent button arrangement in system messages.
- BG-I50021: Fixed missing maximum device count text in TreeTurbo captions within the Periphery tree.
- BG-I49983: Fixed API connector drag-and-drop behavior when switching pages during insertion.
- BG-I48985: Statistics configured as “Each change (max 1 per minute)” now correctly flush suppressed values at the next minute boundary.
Climate
- BG-I49677: Deprecated heating and cooling period defaults are no longer created and can now be removed.
- A3D9-T1144: SOT is now ignored when at least one IRC is below the frost protection temperature.
- Fixed AC Unit Controller not turning off when fan speed is set to “Off”.
- BG-I46128: Fixed IRC remaining in Building Protection after disabling Away Mode.
Lighting
- BG-I50071: Fixed LiCo remanence not working when using the LC input.
- BG-I48956: New DALI Extensions now default the lamp state update cycle to 600 seconds.
Energy
- Car Charger device address settings now hide the /dev/udp prefix and restore it automatically when required.
Security
- BG-I49640: Fixed AAL Smart Alarm losing selected buzzer alarm outputs after saving.
Gateway Client
- BG-I49555: Fixed Device Monitor not applying user permissions to Client Miniserver devices.
Devices
- Fixed incorrect online state naming for devices using device variants.
- Fixed Valve and Nano 2 Relay devices being detected as an older hardware generation and updating to incorrect firmware.
Multiplicator
- BG-I49177: Fixed transferred page and device selections being reset when adding a new Miniserver.
- BG-I49766: Fixed editing Touch Pure Flex “Show Input” settings per managed Miniserver.
SD Card
- BG-I49673: Fixed SD Card Manager showing information from the previously selected entry.
Usability
- BG-I49755: Fixed the initial size of the Energy Flow Monitor configuration dialog.
Audio
- BG-I49688: Fixed playback issues when adding multiple wireless speakers to a single player.
- Fixed incorrect Audioserver LED states shown in Config.
- Fixed Spotify room favorites not starting in some grouped environments.
- Fixed Spotify volume transitions when switching between Spotify and TuneIn.
- BG-I50068: Fixed Spotify default account selection after migration to the new eSDK.
- LOXONE Radio now displays station cover art when no track cover art is available.
Plugins
- Segway Navimow (1.0.1)
- Login system status messages are now shown as information messages.
- Region setting changed to a combo box.
- Updated system status message titles.
- Updated translations.
- BMW CarData Integration (0.0.47)
- Region selection changed to a dropdown.
- Removed manual Home Latitude and Home Longitude settings.
- Reworked and localized documentation.
- Improved authorization workflow documentation.
- Localized Periphery tree names.
- Fixed unnecessary re-authorization requests.
- Fixed formatting issues in system messages.
- FIAS PMS Integration (0.9.3)
- Added fallback checkout time setting.
- Arrival and departure values are now exposed as analog inputs.
- Updated ribbon icon and button texts.
LOXONE Config 17.1 Beta 4
New
General
- Reworked the Getting Started wizard UI.
- Added room hierarchy support.
- Added support for nested room groups with configurable icons and ratings (1–10).
- Added navigable group cards in the Rooms tab of the LOXONE App.
- Added support for room favourites within groups based on room rating.
- Added group sorting by rating.
Devices
- Added Touch Controller support for Touch Pure for Nano.
- Added support for Touch Controller IQS7222C.
- Supported devices: Nano IO, Nano Dimmer.
Energy
- Energy Flow Monitor
- Added current total consumer power output.
Plugin
- Segway Navimow Integration
- Added integration for Segway Navimow robotic lawn mowers.
- Requires Miniserver Gen. 2 with firmware 17.1 or newer.
- Supports up to 10 Navimow devices per Miniserver.
Stability
- Reworked the Miniserver Health Check to provide additional diagnostic information.
Usability
- Migrated the Alarm Clock dialog to the modern Qt interface.
- Migrated the Room and Category dialog to the modern Qt interface.
- Migrated the State Text dialog to the modern Qt interface.
- Added support for deleting empty rows.
- Improved column sizing and tooltips.
Miniserver Connection
- Improved the Miniserver connection workflow and credential handling.
- Added support for selecting local or external connection modes.
- Added project context to keychain entries and preserved passwords when switching users.
- Decoupled project keychain usage from project management and connection handling.
- Added My Miniservers for Miniserver-specific credentials.
- Added My Credentials for reusable credentials independent of a Miniserver.
- Added access to My Credentials from the Connect dialog.
- Added support for credentials that are not tied to a specific Miniserver serial number.
- Credential selection now only fills username and password, leaving Miniserver addresses unchanged.
Audio
- LOXONE Radio (Beta)
Fixed
Climate
- BG-I49595: Fixed the bedroom automatic comfort timer end time to run until 12:00 instead of 08:00.
- BG-I49598: Heating and Cooling Controller Mode is no longer pre-selected when added to a project.
Energy
- Energy Manager configuration dialog column sizing fixed.
General
- BG-I49090: Restored Memory Flag delay parameter visibility and independent operation.
- BG-I49469: Updated the Central dialog to use the correct “Display Name” column title.
- BG-I49772: Fixed a configuration lock-up when renaming a room.
- Fixed an issue where optional string settings with regex validation could not be cleared to an empty value.
- Fixed an issue where the Category Caption name was lost when closing the Room/Category dialog.
- Disabled updates for invalid Nano 2 Relay and Valve Actuator Tree versions.
- Fixed drag-and-drop handling where API actors and additional actors could be added to the wrong page.
Gateway Client
- Deprecated non-concentrator clients. Use Multiplicator instead.
Plugin
- BMW CarData (Beta)
- Fixed an issue where the Authorization Required digital output could remain TRUE after a previous authorization cycle ended unexpectedly.
- Cleared the Authorization Required digital output on every successful poll.
- Adapted container creation to BEV, PHEV, and ICE vehicles instead of using a fixed descriptor set.
- Fixed data retrieval issues on affected vehicle models (e.g. i4 G26).
- Added fallback descriptor probing when BMW rejects the initial container.
- Added validation to detect silently omitted descriptors in BMW responses.
- Added startup health checks for cached containers and cleanup of stale containers.
- Improved handling of transient BMW Apigee gateway HTTP 5xx responses during the OAuth device code flow.
- Fixed orphaned LxBMW processes after program restart by ensuring clean plugin shutdown.
- Improved reporting of authentication and polling errors.
- Removed obsolete Battery Capacity and Battery Energy documentation references.
- Documented Cable Connected and Charging Power as vehicle-dependent values.
Usability
- Pressing Enter in the My Miniservers and Connect to Miniserver dialogs now triggers Connect.
Audio
- Removed the LOXONE Radio listing from the Radio section.
- BG-T5148: Added a cover art minification option for Room Favourites.
- BG-I49797: Removed unnecessary event loading on the WebSocket connection.
- BG-I49809: Fixed an issue where invalid Room Favourite IDs could be set via the API.
LOXONE Config 17.1 Beta 3
New
Access
- Intercom: Added new “Doorbell Ring Preview” setting to control whether the app shows a still image or live video when the doorbell rings.
- Still image is the default and captures the moment the doorbell was pressed.
- Requires app support.
General
- BG-I47171: Automatic Designer: Added conditions for Spot Price Optimizer.
Devices
- Added Touch Pure Flex Gold variants.
- Added AC Control Tree, Hörmann Tree, and Modbus Tree.
- Updated Air Master binaries.
- C7WT-T414: Added Air Base adaptation for Large Update.
- Added new RDC wake-up channel and RDC wake-up improvements.
Fixed
General
- Fixed download of new plugin versions not working. Regression in 17.1.5.28.
- BG-I34091: Fixed DALI device learned in as the 64th device on a fully populated extension taking the broadcast address 255. Existing projects with duplicate broadcast-address devices can now delete the duplicate.
- BG-I47938: User Management API: NFC tags and access codes are no longer editable for trusted users, matching the behavior of the LOXONE App. Only the source Miniserver may modify them.
- BG-I48156: Fixed status block icon colors from older projects not being converted to the current green.
- BG-I49384: Sequence Controller now supports == as equality operator to match formula block syntax while keeping = compatible with existing programs.
- Fixed Modbus Sensors warning when a value in the property window was adapted because the maximum number of fast sensors was reached.
- BG-I47997: Fixed Extension Search in the app not showing Dimmer and 1-Wire Extensions.
- Fixed empty schedules after RTD.
- BG-I49371: Sequence Controller now uses outputs S and TQ when adding custom loggers or trackers.
- BG-I47851: Touch Pure Flex API: Fixed display text switching off after changing a favorite.
- BG-I49429: Managed Tablet: Fixed issue where the green banner in the app could not be turned off.
- BG-I48167: Fixed QuickSearch window staying open for certain dialog actions. The window is now closed before the action is performed.
- BG-I47130: Firmware packages dialog: Fixed configuration dialog showing an empty entry.
- BG-I49048: Fixed editing the name in the property window not immediately updating the control in the view.
- BG-I49166: Fixed some action visibility states not being updated correctly in the Ribbon in some cases.
- BG-I49142: Fixed function block IO description tooltip width not being limited.
- BG-I48866: Fixed importing Belimo device templates from LOXONE Library.
RemoteConnect
- Push notifications are now sent without delay.
Setup
- The uninstaller unins000.exe is now code-signed.
Trust
- BG-I49451: Improved user data synchronization when edited in quick succession, especially for NFC codes.
Stability
- BG-I49223: Fixed a watchdog reboot of Miniserver Gen. 2 that could occur when the DNS or NTP server was configured incorrectly or was unreachable.
- BG-I48015: Fixed a watchdog reboot of Gateway Miniserver Gen. 2 that could occur while saving and sending the program to its clients in some networks.
Exosphere
- BG-I47856: Gateway now correctly returns historical statistics from client Miniservers, including multi-output V2 statistics group files.
Energy
- BG-I48112: Fixed output names in the Energy Manager block being displayed incorrectly when more than two outputs were connected.
- BG-I48285: Meter statistics graph now carries the last recorded value forward through periods without changes instead of showing 0 when the statistic is set to “Record on each change”.
- BG-I49008: Spot Price Optimizer: Fixed cheapest hours for minimum runtime being calculated incorrectly in some cases.
Gateway Client
- BG-I47915: Fixed Expert Mode not opening on Miniserver Gen. 1 client due to timeout.
- BG-I48589: Miniserver task no longer starts without a configured gateway MAC address, and protected commands such as key exchange and password setup are rejected until the gateway MAC address is assigned.
Usability
- BG-I48717: AC API output now accepts an additional connector when a Touch Pure Flex is already connected.
- BG-I48916: Device Status dialog now shows the room for DALI devices.
- BG-I49262: Added missing translations in System Status messages for cabinet and installation location.
- BG-I48871: Load Manager configuration dialog no longer resizes unexpectedly when changing load priorities.
- BG-I49078: Command recognition preview now updates the detected value while editing and keeps the text cursor position stable.
Devices
- BG-I48845: Volume thresholds dialog on Presence Sensor no longer triggers an auto-connect that logs out other users.
- Touch Pure Flex: Input blocks already placed on the program page now refresh their name automatically when a button is reassigned and the configuration is re-imported.
- Updated Presence Sensor Tree binaries.
- BG-I45109: Fixed Presence Sensor keeping presence after power reset.
- BG-I43936: Fixed Presence Sensor not blinking out of the box.
- Updated Shading Actuator Air binaries.
- BG-I40593: Fixed end position setting “Both directions” staying active for only about 1 second.
- Updated Nano DI Tree binaries.
- BG-I44616: Fixed Nano DI Tree not working reliably after POR.
- Fixed first input sometimes being shown as LOW after power loss although it was HIGH.
Climate
- Fixed AC Unit Controller not turning off when fan speed is set to “Off”.
- BG-I49298: AC Central Controller now shows connected Room Controllers.
- BG-I49219: AC Unit Controller: Changing fan speed via IRC or app now ends silent mode.
- BG-I48082: Fan Coil and Central Controllers: Fixed states Ha and Hc not being shown correctly in LiveView.
- BG-I44119: Fixed Leaf Tree not working after Miniserver restart. Program must be saved to the Miniserver again after the update.
Audio
- BG-I47431: Audioserver now reconnects immediately when the secure session is lost.
- Fixed a crash caused by a library.
- Spotify: Fixed incorrect “Account not premium” error message for accounts created in a stack with recent app versions.
- BG-I49076: Fixed Wireless Speaker not showing system temperature.
- BG-I49237: Device Status: Fixed device commands not being sent to the correct device.
Lighting
- BG-I49310: Improved Light Controller history description for blocked presence automatic due to active mood.
LOXONE Config 17.1 Beta 2
New
Lighting
- Lighting Controller – add light circuit inputs LC5-LC8
BMW CarData
- Integrates BMW vehicle data into the LOXONE Miniserver
- One-time authorization via BMW account using device code flow
- Provides vehicle signals: state of charge, electric range, mileage, door lock status, charging state, distance from home and more
- Manual polling trigger to fetch vehicle data on demand (BMW CarData API limit: 50 requests/day per vehicle)
- Supports up to 20 vehicles per Miniserver
Diagnostics
- Added possibility to save PDF report of Health-Check/Device-Diagnostics results
Audio
- R1701-T111: CPU Temperature diagnosis input for Audioserver and connected audio devices
Planning
- Added new Leaf Tree/Air articles
- Added automatic calculation for Leaf ventilation
- R1701-T78: New room type “Outdoor Area” for outdoor spaces
Energy
- BG-I47277: Peak Load Manager
- New Output “Available Power Peak” (ApPeak) which starts with MaxTp at the beginning of the interval and gradually decreases to meet power budget MaxP
- Load Shedding now uses ApPeak for calculations
- Input Gpwr can be used to add PV export power to Ap/ApPeak outputs when negative
Usability
- R1701-T1: Naming of function blocks
- Auto rename (IRC, AudioZone, AudioZoneV2, LightController V1, LightController V2, Presence, AC Control) to have the room name
- On creation
- On room name change
- On room change
- Converted old programs accordingly
- Show device IP/address in a newly added Info column of the Device Status dialog
Climate
- BG-T4902: Intelligent Room Controller – Automatically adapt comfort range for only heating or only cooling capabilities
Fixed
General
- BG-I48695: Managed tablet drag and drop does not work.
- BG-I48818: Irrigation block doesn’t save time settings the first time you change them.
- BG-I48950: KNX Extension group address count above 500.
- BG-I48085: IRCs do not display values for the valve actuators on outputs connected to FCFC or FCC.
- BG-I48800: Nano 2 Relay Tree shows current flow when set to shading type.
- BG-I48741: GETINPUT now returns the connected IRC2 humidity and CO2 input values.
- BG-I47101: Sequence controller: wrong popup about changes.
- BG-I48934: Automatic Designer/Scenes: Managed Wallbox shows charge mode actions.
- BG-I42982: Presence: Parameter TWarn not validated against Pet.
- BG-I45729: Presence: prevent acoustic reactivation while control is locked.
- BG-I48528: App Control: add description for universal links to Url setting.
- BG-I49283: File upload timeout increased to 2 minutes to fix upload failures on Miniserver Gen1.
- BG-I48460: Backup files in the Project Backups dialog are now sorted correctly by date.
- BG-I47928: AutoConfig now switches to the Periphery tree when showing unassigned peripherals.
- BG-I47131: System status date is now displayed in the system language instead of always English.
- BG-I48949: Periphery tree online indicator now shows “Online” tooltip, consistent with the “Offline” tooltip shown for offline devices.
- BG-I48238: Changing the name setting in property window didn’t set document’s modified flag in all cases.
- BG-I48065: Project backup dialog didn’t show creation date correctly.
- BG-I48771: Opening Miniserver update dialog switched selected ribbon category.
- BG-I48622: Editing a function block immediately after copy&paste edited the previous function block.
- BG-I48596: Fixed incorrect column layout/width in NewMiniserver page table.
- BG-I48516: Connecting to a Miniserver from the NewMiniserver page table didn’t prefill its IP address in the dialog.
- BG-I48829: added missing AC Control monitor action to context ribbon.
- BG-I48066: fixed incorrect/truncated project backup folder name when project name contained dots.
- BG-I48791: fixed missing dialog buttons in some cases.
- BG-I47858: corrected tooltip behavior in property window (text editors and comboboxes).
- BG-I47609: MessageBoxes were automatically closed by Exo loading dialog (due to incorrect auto parent selection).
- BG-I48984: incorrect ribbon context panel shown when selecting “Touch” caption under Nano Dimmer Air devices.
- BG-I48155: LICO: Buzzer history creates 2 entries for short pulses.
- BG-I48348: AC Unit Controller: forward thetaC visible even when AC Control device is not used.
- BG-I48366: The API connector reference cannot be deleted from Fan Coil Unit Controller.
- BG-I48365: After deleting the API connector reference, the connection is still shown.
- BG-I48148: The formula module shows the message ‘invalid formula’ since the update to version 17.
- BG-I47861: updated nomenclature for Automatic shading outputs in “Automatic Designer”.
- BG-I48048: Update dialog no longer offers to load the project from the Miniserver when the local project is newer.
- BG-I48100: Statistics CSV export from Config now includes the unit in column headers (e.g. “Input Statistics [°C]”).
- BG-I48107: Schedule from presets now appear in other project.
- BG-I48254: fix IRC Block Default Fan Speed when FC Unit Controller is connected.
- BG-I48469: MinMax V1 now compares with V2 when not connected.
- BG-I48649: SPD Temperature Send Cycle setting accepts 0 “Off”.
- BG-I48563: Text Generator Output now updates time.time.
- Crash when saving into Miniserver with child network devices.
- BG-I47510: Managed tablet changed brightness after update.
- BG-I47383: Modbus TCP: Receive timeout system message was not set to historic if sensors were removed from the program.
Usability
- BG-I48570: Wrong error message was shown when user did not have sufficient rights via Config.
- BG-I46828: Floating property window now selects the target block so it remains identifiable behind the filter.
- Statistics CSV export now shows an error dialog when a target file can’t be written instead of failing silently.
- R1701-T77: Hide Memory Flag delay setting when it has the default value.
- R1701-T79: Reposition connected references when showing/hiding function block inputs/outputs.
- R1701-T84: System message descriptions now clearly label room, installation place and device type.
- BG-I48539: Fix SD Card Maintenance dialog freezing after deleting files.
- BG-I45559: Fix property window not updating while an SD card is being formatted.
- Fix incorrect window title shown in the Changelog dialog.
- Backspace now removes selected items, like the Delete key.
Climate
- BG-I42067: Heating and Cooling Controller: invalid operating mode when input was changed while control is locked.
- BG-I48837: Fan Coil Central Controller – prepare separate thresholds for app.
- AC Unit Controller can not be switched off in standalone mode.
- Fan Coil Central Controller – capability-bitmask not set.
- Intelligent Room Controller – cooling capabilities not set for Fan Coil Unit Controllers.
- BG-I48341: Intelligent Room Controller – add connection bit to target temperature input.
- BG-I48293: Outdoor temperature stuck on Fan Coil Central Controller.
- BG-I47967: FCCc in the app shows incorrect information when Otm = 0 (disabled).
- BG-I47881: FCC, FCFC and FCCc use the same abbreviation despite different functions.
- BG-I46496: Up/Down arrow in IRC Air control is not always reacting correctly.
- BG-I48477: ACc keeps IRC connection when copied when it should not be there.
- Intelligent Room Controller – change of fan speed not always forwarded to AC Unit Controller.
Lighting
- BG-I48166: DMX brightness drops in CW/WW mixing range despite Miniserver commanding 100%.
Devices
- BG-I40274: Leha shading isn’t working reliably.
- Nano Motor Controller Air/Tree new binaries: 17.01.05.11.
- Telemetry not reactivated.
- BG-I45000: NFC behavior if two different NFCs are connected to one Anfc.
- BG-I45020: Wrong popup when inserting T2AB to Wallbox Air.
- Touch Tree, Touch Pure Tree and Touch Pure CO2 Tree occasionally did not respond to touches.
- BG-I46364: Touch Pure Air – Backlight actor not removed when device is battery operated.
- Power Supply and Backup: New binary 17.01.04.28.
- BG-I25399: Device reset sometimes during TechReport webservice polling.
- BG-I27829, BG-I33447, BG-I39476: False “Backup active” / “Fuses blown” in supply-only mode on mains loss.
- Smoke Presence Detector Air/Tree EU new binaries 17.01.05.07.
Audio
- BG-I48176: Some source changes not correctly promoted among stacked devices.
- BG-I49201: Wrong blink state on Audioserver fixed.
- Bluetooth: connecting to muted player groups caused all players to start, should only happen on fixed groups when services are managed by the group itself.
- Bluetooth: connection to non-grouped player failed.
- BG-I49076: Wireless Speaker does not show system temperature.
- BG-I49237: Device Status – Device Commands not sent to correct device.
- Live Learning – Wireless Speaker not replaceable.
- BG-I48765: Device Status: invalid icon for Miniserver Compact.
- BG-I46916: Tree Turbo devices are not shown as online in tree when learned in via app.
- BG-I47646: Audio Player wrong history message when presence active and playback paused.
- Fixed issue for Stereo Extensions in split mode not working after EQ revert.
- Equalizer reverted to old implementation & loudness removed.
Exosphere
- BG-I48668: Exo login in Config was not possible.
- Exosphere (1.3.3):
- Improvement: If double values are above 1.0000000000000000e+256, the message is ignored.
- Improvement: Double values are rounded to 3 decimal places.
- Fix: Plugin Obsolete message did not disappear after plugin was active again.
Modbus
- BG-I48320: Modbus TCP now correctly allows up to 300 actors instead of the RTU limit of 254.
Energy
- BG-I48272: Meter / Pulse Meter – meter reading offset (Mro) no longer leaks into day/week/month/year statistics.
- BG-I48053: Energy manager calculation with Min. runtime calculates wrong ramp-up values.
- R1701-T2: Negative residual values in the Energy Flow Monitor are no longer counted as production when at least one producer is configured.
- Peak Load Manager: Fixed premature interval elapsed timing that could cause incorrect Available Power (Ap) calculation shortly before the interval end.
- BG-I48275: Restore Type column position in the Energy Flow Monitor dialog.
Stability
- BG-I48838: Miniserver Gen.1 reboot when using Valve Tree Devices.
- BG-I48223: Improved SSL send when receiver is busy which caused updates not being able to transfer to clients in some cases.
- BG-I47512: Fix occasional crashes triggered by Windows accessibility tools.
- BG-I47640: Config crash when entering Live View.
- BG-I47463: Fix occasional Config crash when the project messages list is updated.
Planning
- BG-I47916: New Touch Pure and Touch Pure Flex devices could not be edited with comboboxes.
Honeywell
- Honeywell Plugin 1.0.3
- BG-I48139: Fixed disconnect deadlock when logout command could not be sent due to websocket problem.
LOXONE Config 17.1.4.29 Beta 1
New
General
- Smoke & Presence Detector Air/Tree.
- A3D9-T2290: Simplified “Installation Location” handling.
- Removed for devices that act at their installation point (e.g. Touch Tree → location defined by device name).
- Kept for devices controlling elements in other locations (e.g. Nano Relay, RGBW Dimmer → separates physical installation vs. controlled location).
- Existing projects remain unchanged (configured installation locations are preserved).
- A3D9-T2171: Sauna Controller: Added support for DisplayEcho.
Plugin
- Fronius Plugin (1.4.27):
- New: Verification of AC output power limits and notification if control is non-functional.
- New: Updated documentation.
- Fixed: Optimized error handling and system stability.
Devices
- Device Telemetry – sends device diagnostics information to LOXONE.
- Can be activated in the document with the setting “Enable Device Logging”.
- While active, a remote server defines which device types or specific serial numbers are monitored.
- Monitored devices send cyclical diagnostic information to the Miniserver, which forwards it to a cloud server.
- Communication is encrypted and does not contain sensitive data.
- Wallbox Air/Tree new binaries.
- BG-I37350, BG-I41202: Fixed charging error; simplified pilot circuit was not detected correctly.
Fixed
General
- BG-I43835: Automatic rules automatically reactivate after restart/update.
- BG-I48228: Property window “Device Type” is shown when an IO of a device is selected.
- BG-I48284: Central Audio – negation of the OFF input blocks only inputs, not AP.
- BG-I46736: Miniserver Client is reported as offline.
- BG-I44570: DispPc from switch does not block OFF input.
- BG-I42026: Peak Load Manager: Very high power after power outage test.
- BG-I48149: Central inputs fixed when user interface password is enabled.
- BG-I48161: Fire & Water Alarm does not trigger on negative maximum temperature values.
- BG-I47783: Text Generator – <time.date> shows incorrect date after 10 PM.
- BG-I43675: Wallbox Air: NFC Code Touch Tree update does not complete.
- BG-I47517: Intelligent Room Controller – history now differs between heating and cooling preparation phases.
- BG-I47516: System messages – adapted description of severity of custom system messages.
- BG-I47333: Intelligent Room Controller – statistics show wrong unit in the app.
- Energy Flow Monitor – meters not shown correctly in regular visualization.
- BG-I47968, BG-I47998: Removed error code from Client/Gateway error message.
- BG-I47999: Fixed blank error message when entering Client/Gateway mode with different credentials.
- Fixed race condition when waiting for logon response from Miniserver.
- Fixed HTTP requests sent from Config to Miniserver not using Basic Auth headers, causing issues with HTTPS redirect.
- BG-I47321: Miniserver replace not working when Miniserver has factory credentials and HTTPS redirect enabled.
- BG-I47249: Miniserver queries register.loxonecloud even though RC is disabled.
- BG-I47677: Tab is not escaped in device status message.
- BG-I46915: Fixed language mismatch warning reappearing after saving to Miniserver within the same session.
- BG-I47939: Message box dialogs opened with incorrect size in some cases.
- BG-I47971: Action to unregister all push devices was not always correctly enabled.
- BG-I47907: Object configuration dialog could be resized below its minimum size.
- BG-I47877: Property window read-only text editor appeared to overlap property labels.
- BG-I47865: Selection was not correctly updated when editing an object by double-click.
- BG-I47862: Property window stopped repainting after Help View was opened in some cases.
- BG-I47791: Removed “Insert Extension” action from “Tree Turbo” ribbon context panel.
- BG-I48047: Exosphere projects are now appended instead of prepended to the project list.
- BG-I47940: Quick Access panel hid certain actions upon opening a project.
- BG-I48138: Managed Tablet setup code dialog was not correctly positioned upon opening.
- BG-I47693: User group “Nobody” visible in multi-edit dialog when editing all user groups.
- SKY language contains an incorrect character in the language menu.
- BG-I47375: Authentication error def.log entries improved.
- BG-I47897: Fixed CLxStringU comparison operators performing pointer comparison instead of string comparison.
- BG-I46609: Fixed interfering tooltips in the property window.
- BG-I47420: Fixed combobox rendering in table/tree views on Windows 11.
- BG-I46953: Update notification panel missing buttons in some cases.
- BG-I47465: Time editor returned incorrect value when AM/PM format was used.
- BG-I47440: Entire row is now selectable in Tree Views.
- BG-I43804: Added button to abort an ongoing connection attempt to the Miniserver.
- BG-I47492: Fixed possible crash when switching actor type of a DALI device.
- BG-I47753: SD format dialog failed when “overwrite data” was selected.
- BG-I47429: HVAC Controller – fixed Y2 output description for “Heat Pump with Electric Backup”.
- BG-I47143: App – WSP appears in Tree Turbo search.
- BG-I47343: Adding Presence Sensor Air and teaching in a battery-powered device shows inputs from a 24V device.
- BG-I47443: Repeating Auto Config removes backup mode.
- BG-I47538: Gate: Opening/closing duration set to 0 causes the gate to never stop.
- BG-I46911: Virtual HTTP Input – chunked HTTPS response not properly handled.
- R20-I20: Valve Actuator Tree status LEDs could not be disabled.
- BG-I46277: New custom message box implementation to fix layout issues.
- BG-I47398: Names for Rooms/Categories are not correctly converted to Unicode in the ribbon.
- BG-I46760: Lighting Controller now shows “Not fully configured” when no settings are configured.
- BG-I46584: Stereo Output 1 is always named as Audioserver when connected to the AP block.
- BG-I46419: Text Generator – incorrect time in Live View.
- BG-I46895: SPO: Currency for CH markets (CKW, EKZ, Group E) shows EUR instead of CHF.
- BG-I46921: Audio Player function block displays assigned devices incorrectly in some cases.
- BG-I44547: Live View: Negated outputs and switches not working for some outputs.
- BG-I46957: Auto Config replaces one of your custom light moods.
- BG-I47041: Planning Tool: Some Signal White devices are missing.
- BG-I46223: LED blink position calculated incorrectly due to installation and Tree branch sorting.
- BG-I47539: IRC – fan speed presence setting has no name in expert mode.
- Some icons and colors were outdated.
- BG-I47438: Velvet White Touch Pure Flex does not show correct inputs after updating from Configurator.
- Users with update rights are not allowed to change the update level.
- BG-I47216: Monitoring online status cannot be disabled for Modbus TCP devices.
- BG-I47417: TPF on Intercom – fixed incorrect reference names for devices.
- BG-I48288: Air Diagnostics not working properly.
- BG-I48306: Air Diagnostics showing unknown devices.
- BG-I47507: Existing network devices are shown in the search dialog when the hostname uses a local TLD.
- BG-I48437: Download Exosphere project dialog did not automatically close properly in all cases.
- BG-I47853: Ribbon action to save a template was incorrectly displayed for certain selected devices/objects.
- BG-I47832: Audioserver is created as a Wireless Speaker when generating a part list from a configuration.
- BG-I48067: Audio device configuration contains incorrect grammar in the German version.
Climate
- BG-I46532: Heating and Cooling Controller in Gateway Client switches to OFF when saving to Miniserver in some cases.
- BG-I47803: FCCc – theta LimC and theta LimH positions swapped in the app.
- BG-I48082: FCC, FCFC, FCCc show incorrect values on Ha and Ca inputs.
- BG-I47766: IRC shown as actively heating even if heating is not available.
- BG-I47513: IRC2/HCC – pulse on Eh causes continuous overheating request.
- BG-I46613: Heating and Cooling Controller does not transfer heating/cooling block when Otm parameter is set by logic.
- BG-I45992: IRC – using all configured sources simultaneously did not start the AC controller in some cases.
- BG-I47724: AC Unit Controller does not become active after being locked via the OFF input.
- Intelligent Room Controller – invalid fan speed on input/in the app when using multiple AC Unit Controllers.
Planning
- BG-I47914: Wireless speaker missing in global preselection in project planning.
- BG-I47497: Missing products in project planning (Door Lock Air, NFC Velvet White, Intercom Velvet White, Wall Speaker White).
- BG-I47297: Dimmable Output 24VDC missing in global preselection.
AutoConfig
- BG-I47918: Lighting Controller shows duplicated entries after re-run.
- BG-I47972: Some comfort functions are preselected.
- BG-I48278: Central Heating page has incorrect name and category.
- BG-I47686: Inserts incorrect ToDo and adds night mode information.
Setup
- BG-I48077: Allow installation when the install directory is accessed via a symlink by disabling RedirectionGuard.
- BG-I47902: Delete stale ProgramData content when upgrading an existing installation.
Gateway-Client
- Client states are invalid when the client runs an outdated version.
- Miniserver Gateway always transfers the update file to its Gen.1 clients in streaming mode, which results in transfer issues.
- This occurred because the update file size exceeded 30 MB.
Stability
- Miniserver crash when generating structure file with Audio Players in use.
- BG-I47427, BG-I47602: Crash in async undo thread due to concurrent document access.
- BG-I47703: Miniserver crash when sending intercom push notifications with modified users/groups.
- BG-I48017: Miniserver watchdog triggered by race condition.
- BG-I48021: Miniserver crash when closing TCP sockets.
- Fixed property window rendering stale content when opening Qt dialogs.
- BG-I47474: Config freeze after uploading custom certificate.
- BG-I48153: Saving Virtual Out HTTP response files on Miniserver Gen.1.
- Possible Miniserver crash when receiving Tree packets.
- Config crash when opening User Management dialog.
- BG-I47439, BG-I47447, BG-I47484, BG-I47509, BG-I47519, BG-I47558, BG-I47534: Multiple crash fixes (use-after-free, threading, Live View, startup, UI interaction).
- Fixed crash on application close due to QNetworkAccessManager thread.
- BG-I47156: Miniserver crash triggered by malformed encrypted command.
- Config crash when receiving new Partner Message Center entries.
- BG-I48490: Miniserver crash when data is received from a plugin.
- BG-I48222: Fixed crash on mouse release when Live View or Miniserver reconnect destroys the clicked control object.
Energy
- Energy Flow Monitor – residual values not shown for sub-meters.
Audio
- New equalizer allows more precise control of single bands.
- BG-I48313: Extension LED remains orange blinking.
- BG-I47761: Audio Player does not send volume configuration in certain gateway constellations.
- BG-I47992: Fixed incorrect “Project modified” notification when closing dialog without changes.
- Master/Client Speaker: Audio dropouts fixed.
- Wireless Speaker: Update progress reporting fixed.
- Event volumes slightly increased to match playback volume.
- Wireless Speaker: Static IP configuration not applied correctly.
- Wireless Speaker: DHCP hostname registration fixed.
- Wireless Speaker: Fixed Bluetooth fallback when WiFi is down.
- Fixed race conditions and crashes related to AudioServer playback, AirPlay, and Bluetooth handling.
Devices
- Touch & Grill does not show correct battery value outside function block.
- BG-I47768: Volume thresholds graph not working after reset.
- BG-I45340: Tree does not show devices available for pairing if already paired on another branch.
- BG-I45162: Valve Actuator Air/Tree Gen. 2: Start position detection can be disabled.
- BG-I46362, BG-I46639: Valve Actuator Air/Tree Gen. 2: Some devices could not fully open.
- BG-I47995: Live Learning – replaced devices are shown again after restarting the search.
Usability
- BG-I47390: Fixed checkbox display in Windows 11 update dialog.
- BG-I48200: Native language names display correctly in language switcher.
- BG-I47625: Checkboxes in SD card dialog disappearing when selected.
- BG-I46328: Miniserver configuration window position inconsistency fixed.
- BG-I46961: Sequence Controller indentation reduced.
- BG-I41904: Prevent background scrolling when dialogs are open.
- BG-I46931: Prevent multi-edit dialogs from reopening after close.
- Restored main window geometry before show().
- Fixed incorrect tooltip text in user management dialog.
Exosphere
- Fixed repeated workspace requests caused by infinite retry loop (401 Unauthorized).
- R1701-T9: Statistics of controls on a Client Miniserver are now returned correctly.