Security Overview

USE

The Security Overview block can be used to control other burglar alarm blocks.

BASIC PROGRAMMING

By double clicking on the block, you will open this window

Here you need to select wich Burglar Alarm function blocks you wish the Security Overview to be able to control and show control for in the User Interface.

Central commands from blocks like this are also not inhibited by an active Dis input on the respective module. The Dis input only refers to the input connections on the left side of the blocks themselves. The program blocks can still be operated via the user interface and the overview block.

If a program block is used in the central module, this is indicated by the central symbol on the respective module in the top right-hand corner. In addition, the device name in which it is used is specified when hovering over for further information.

INPUTS

Abbreviation Summary Description Unit Value Range
Tr Trigger including motion sensors Arms / Disarms the burglar alarm with Motion Sensors A single pulse immediately arms / disarms alarm system (toggle) Motion sensors are included and can trigger the alarm Digital 0/1
TrNm Arm/Disarm without Motion Sensors Single pulse arms/disarms the alarm without Motion Sensors A single pulse immediately arms / disarms alarm system (toggle) Motion sensors not being used to trigger alarm (i.e. Night Mode) Digital 0/1
A Arm including motion sensors Single pulse arms the burglar alarm including motion sensors Digital 0/1
ANm Arm without motion sensors Single pulse arms alarm system without motion sensors Digital 0/1
V Trigger delayed arming including motion sensors Single pulse arms alarm system with delay including motion sensors. The duration of the delay is defined with the parameter “Da” Digital 0/1
VNm Delayed arm without motion sensors Single pulse arms alarm system with delay without the motion sensors. The duration of the delay is defined with the parameter “Da” Digital 0/1
R Reset Single pulse disarms alarm system This will also cancel any active alarm Digital 0/1
C Trigger Acknowledge Acknowledge Alarm The current alarm and outputs Q1-Q6 are deactivated The alarm system, however, remains armed and the alarm is reactivated only when another detector is triggered Digital 0/1
Dis Disable Disable input of the burglar alarm (child lock) Locks all inputs to the block in configuration but does not disable access via the app Digital 0/1