Radio Buttons (16x)

Up to 16 radio buttons, only one output can be active at a time. For example, pulse at input (I3) activates (O3).

Table of Contents


Inputs

Abbreviation Summary Description Value Range
I1-16 Input 1-16 Switches the respective output 1-16 On. -
+ Next output 0/1
- Previous output 0/1
Sel Select output Switches to specific output. 0...16
Off Off Pulse: Outputs are reset / switched off.
On: Block is locked.
Dominating input.
0/1
DisPc Disable periphery control Disables all inputs when On. (e.g Child lock, cleaning)
Control via user interface is still possible.
0/1




Outputs

Abbreviation Summary Description Value Range
O1-16 Output 1-16 -
N Number of active output 0...16
AC API Connector Intelligent API based connector. -




Parameters

Abbreviation Summary Description Value Range Default Value
Rem Remanence input Remanence input: If active, the function block retains its previous state after a Miniserver reboot. 0/1 0
Max Max. outputs Maximum number of used outputs when using +/- inputs. 0...16 16
Sk0 Skip 0 'All-off' (0) is skipped when switching with +/- when On. 0/1 0




Properties

Summary Description Default Value
Edit outputs Edit output names -




Application

The Radio Buttons module can also be used directly within the visualization (Web Interface / App). By double-clicking on the block, the display texts can be edited.