Alarm Siren Tree

The Alarm Siren Tree is an external warning device with strobe light, for example as part of the burglar alarm. When triggered, the device emits an audible and visual alarm. The integrated tamper switch provides additional protection.

Datasheet Alarm Siren Tree

Table of Contents


Mounting↑

Select an installation location where the device is protected from extreme weather conditions and damage. Make sure that the cable outlet is covered by the unit after installation.

Connect the power supply (orange/white) and Tree communication wires (green/white) using the supplied 3M jelly crimp connectors. The wires including insulation are inserted into the connector, then the connector is crimped with pliers.

To complete the installation, place the top cover on the base unit and secure it to the bottom with the two screws.


Commissioning↑

Shortly after power-up, the status LED will blink orange if the wiring is correct and a connection to the Miniserver (Tree Extension is online) has been established.

Then follow the pairing procedure


Sensors↑

Summary Description Value Range
Tamper switch Input is active in normal state. The input is deactivated when sabotage is detected by the contact on the device. 0/1




Actuators↑

Summary Description Value Range
Alarm light Output to activate the alarm light 0/1
Alarm sound Output to activate the alarm sound 0/1




Diagnostic Inputs↑

Summary Unit Value Range
Online Status Alarm Siren Tree Digital 0/1




Properties↑

Summary Description Unit Value Range Default Value
Monitor Online Status You will be notified via System Status or Could Mailer if the device is no longer available or offline.
As this device and it's functionality are critical to safety, it is not possible to disable this setting for this device.
- - -
Serial Number Specifies the serial number of the device.
For Extensions: Enter 'Auto' to automatically pair an extension with unknown serial number.
This can only be used if there is only one Extension of the same type.
Save into the Miniserver, in order to pair the Extension.
Afterwards the program must be loaded from the Miniserver to transfer the actual serial number of the Extension into the program.
- - -
Device type Tree device type - - -
Maximum audible alarm duration [s] Maximum audible alarm duration (0 - 1800 seconds, 0 = no limit) s 0...1800 120




Safety Instructions↑

When connecting to an external power supply, the installation must be carried out by a qualified technician in accordance with all applicable regulations.

The device must not be used as part of safety-critical systems.


Documents↑

Datasheet Alarm Siren Tree