The Alarm Siren Tree is an external warning device with strobe light, for example as part of the burglar alarm. When triggered, the device emits an audible and visual alarm. The integrated tamper switch provides additional protection.

Datasheet Alarm Siren Tree

Table of Contents


Mounting

Select an installation location where the device is protected from extreme weather conditions and damage. Make sure that the cable outlet is covered by the unit after installation.

Connect the power supply (orange/white) and Tree communication wires (green/white) using the supplied 3M jelly crimp connectors. The wires including insulation are inserted into the connector, then the connector is crimped with pliers.

To complete the installation, place the top cover on the base unit and secure it to the bottom with the two screws.


Commissioning

Shortly after power-up, the status LED will blink orange if the wiring is correct and a connection to the Miniserver (Tree Extension is online) has been established.

Then follow the pairing procedure


Sensors

Summary Description
Tamper switch Input is active when tampering is detected




Actuators

Summary Description
Alarm light Output to activate the alarm light
Alarm sound Output to activate the alarm sound




Diagnostic Inputs

Summary Unit
Online Status Alarm Siren Tree Digital




Properties

Summary Description Unit Value Range Default Value
Monitor online status You will be notified via System Status or Could Mailer if the device is no longer available or offline.
As this device and it's functionality are critical to safety, it is not possible to disable this setting for this device.
- - -
Serial number Specifies the serial number of the device.
For Extensions: 'Auto' may only be used if only one Extension of this type is being used.
- - -
Device type Tree device type - - -
Maximum audible alarm duration [s] Maximum audible alarm duration (0 - 1800 seconds, 0 = no limit) s 0...1800 120