Sequencer

Trigger switches the next output on.

Table of Contents


Inputs

AbbreviationSummaryDescriptionValue Range
TrTriggerSwitches the next output on.0/1
PPositionChooses a specific output0...8
RResetWhen 1 (O) = (Dv)0/1
DisPcDisableDisables inputs (Tr) and (P) when On. (Child lock)0/1




Outputs

AbbreviationSummaryValue Range
O1-8Output 1-80/1
SelSelected output0...8




Parameters

AbbreviationSummaryDescriptionValue RangeDefault Value
RemRemanence inputRemanence input: If active, the function block retains its previous state after a Miniserver reboot.
The state of the function block is saved:
– When saving to the Miniserver
– At a planned reboot
– Before a backup
– Once per hour
The data is saved on the SD card.
0/10
MaxMaximum number of used outputs0...88
DvDefault valueOutput that should be set when (R) is triggered (0 = all OFF)0...81