Alarm Siren Air

The Alarm Siren Air is an external warning device with strobe light, for example as part of the burglar alarm. When triggered, the device emits an audible and visual alarm. The integrated tamper switch provides additional protection.

Datasheet Alarm Siren Air

Table of Contents


Mounting

Select an installation location where the device is protected from extreme weather conditions and damage. Make sure that the cable outlet is covered by the unit after installation.

Connect the power supply (orange/white) using the supplied 3M jelly crimp connectors. The wires including insulation are inserted into the connector, then the connector is crimped with pliers.

To complete the installation, place the top cover on the base unit and secure it to the bottom with the two screws.


Commissioning

In delivery state, pairing mode will be active after the power supply has been established. This is indicated by the status LED flashing red/green/orange.

Then follow the pairing procedure on the Air Interface.

To activate the pairing mode manually, switch off the power for 10 seconds, then switch it back on. If no connection to a Miniserver can be established for two minutes, then pairing mode is activated. The device can then be paired again.


Sensors

SummaryDescriptionValue Range
Tamper switchInput is active in normal state. The input is deactivated when sabotage is detected by the contact on the device.0/1




Actuators

SummaryDescriptionValue Range
Alarm lightOutput to activate the alarm light0/1
Alarm soundOutput to activate the alarm sound0/1




Diagnostic Inputs

SummaryDescriptionUnitValue Range
Online Status Alarm Siren AirIndicates whether the device can be reached by the Miniserver.
Diagnostics for Air devices
Diagnostics for Tree devices
Diagnostics for Extensions
Digital0/1




Properties

SummaryDescriptionUnitValue RangeDefault Value
Monitor online statusYou will be notified via System Status or Could Mailer if the device is no longer available or offline.
As this device and it's functionality are critical to safety, it is not possible to disable this setting for this device.
---
Serial numberSerial number of Air device.
Automatic pairing can be enabled on the Air Base.

Automatic pairing can be enabled on the Airbase for a set time.
---
Maximum audible alarm duration [s]Maximum audible alarm duration (0 - 1800 seconds, 0 = no limit)s0...1800120



Safety Instructions

The installation must be carried out by a qualified technician in accordance with all applicable regulations.