Push-button (double) +/-

Using the program block push-button (double) +/-  an analog value can be gradually increased or decreased using the user interface or physical switches.

Loxone Musterkoffer


Input + increases and input - decreases the analogue value at output AQ by the step size which is set by the parameter SI between the Min and Max analogue range. 

A long press at the inputs + and - will increase or decrease the output faster by repeating the adjustment by the step size over and over until the press is released.

The input P allows the value at AQ to be set directly. If for example P has a value of 5 then the output AQ will be value 5.

A pulse at input R will reset the output AQ to the default value which is set by the parameter D. If the Dis input is on then the inputs of the block will be disabled.